TROUBLESHOOTING

®

R 15 E UK

PORTABLE FORCED AIR HEATER

TROUBLESHOOTING

See Pump Pressure Adjustment, page 8 WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

OBSERVED FAULT

POSSIBLE CAUSE

REMEDY

Heater ignites, but flame-out control shuts

1.

Wrong pump pressure

1.

See Pump Pressure Adjustment, page 8

off heater after a short period of time

2.

Dirty air output, air intake, and lint filters

2.

See Air Output, Air Intake and Lint Fil-

 

 

 

 

ters, page 7

 

3.

Dirty fuel filter

3.

See Fuel Filter, page 8

 

4.

Dirt in nozzle

4.

See Nozzle, page 9

 

5.

Dirty photocell lens

5.

Clean photocell lens

 

6.

Bad flame-out control

6.

Replace flame-out control

 

 

 

 

 

Heater will not ignite, but motor runs for a

1.

Wrong pump pressure

1.

See Pump Pressure Adjustment, page 8

short period of time

2.

Carbon deposits on spark plug and/or

2.

See Spark Plug, pages 8

 

 

improper gap

 

 

 

3.

Dirty fuel filter

3.

See Fuel Filter, page 8

 

4.

Dirt in nozzle

4.

See Nozzle, pages 9

 

5.

Water in fuel tank

5.

Drain and flush fuel tank with clean

 

 

 

 

kerosene. See Storing, Transporting, or

 

 

 

 

Shipping, page 5

Shipping, page 5 WARNING: High voltage!

6.Electronic ignitor not grounded (earthed)

7.Bad electronic ignitor

6.Make sure electronic ignitor mounting is tight.

7.Replace electronic ignitor

Motor does not start when heater is plugged 1.

Flame-out control not reset

1.

Reset flame-out control button, see Fig-

in, fan rotates slowly or does not turn

 

 

ure 3, page 5

2.

Binding pump rotor

2.

If fan is hard to turn, see Pump Rotor,

 

 

 

page 9

6