SAFETY INFORMATION

Continued

14.Keep heater at least 6 feet (1.8 m) from pro- pane tank(s). Do not point heater at propane tank(s) within 20 feet (6 m).

15.Keep propane tank(s) below 100° F (38˚ C).

16.Check heater for damage before each use. Do not use a damaged heater.

17.Check hose before each use of heater. If highly worn or cut, replace before using heater.

18.Do not alter heater. Keep heater in its original state.

19.Do not use heater if altered.

20.Locate heater on stable and level surface if heater is hot or operating.

21.Not intended for use on finished floors.

22.Never block air inlet (rear) or air outlet (front) of heater.

23.Keep heater away from strong drafts, water spray, rain or dripping water.

24.Do not leave heater unattended.

25.Keep children and animals away from heater.

26.Never move, handle or service a hot, operating or plugged-in heater. Severe burns may result. Wait 15 minutes after turning heater off.

27.To prevent injury, wear gloves when handling heater.

28.Never attach duct work to heater.

29.Turn off propane supply and unplug heater when not in use.

30.Use only original replacement parts. This heater must use design-specific parts. Do not substitute or use generic parts. Improper replacement parts could cause serious or fatal injuries.

UNPACKING

1.Remove all packing items applied to heater for shipment. Keep plastic cover caps (attached to inlet connector and hose/regulator assembly) for storage.

2.Remove all items from carton.

3.Check all items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

PRODUCT

IDENTIFICATION

Hot Air Outlet

Shell

(Front)

 

Handle

Motor

Piezo

Ignitor UNPACKINGPRODUCTFigure 1 - 30,000 Btu/Hr Model

Button

Automatic Control

Valve Button

Hose/Regulator

Power

Assembly

Cord

 

Figure 1 - 30,000 Btu/Hr Model

THEORY OF OPERATION

The Fuel System: The hose/regulator assembly attaches to the propane gas supply. This provides fuel to the heater.

The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.

The Ignition System: The piezo ignitor lights the burner.

The Automatic Control System: This system causes the heater to shut down if the flame goes out.

Clean Heated

 

 

Air Out (Front)

Fan

Motor

 

 

 

 

Cool

 

 

Air In

 

 

(Back)

Combustion

 

 

Chamber

 

 

Air For Combustion

Air For Heating

 

Hose/Regulator

 

Assembly

Figure 2 - Cross Section Operational View