MAINTENANCE

WARNING

Never attempt to service heater while it is connected to propane supply, operating, or hot. Severe burns can occur.

1.Keep heater clean.

2.Inspect heater before each use. Check connections for leaks. Apply mixture of liquid soap and water to connections. Bubbles forming show a leak that must be corrected. Correct all leaks at once.

3.Inspect hose/regulator assembly before each use. If hose is highly worn or cut, replace.

4.Have heater inspected yearly by service person.

 

TROUBLE-

 

 

 

WARNING

 

 

 

SHOOTING

 

 

 

 

 

 

 

 

 

 

Never attempt to service heater while it is connected to

 

 

 

 

 

 

 

 

 

 

propane supply, operating, or hot. Severe burns can occur.

 

 

 

 

 

 

 

 

 

 

 

 

SYMPTOM

POSSIBLE CAUSE

REMEDY

 

 

Pilot fails

1. Propane supply valve closed

1.

Open propane supply valve

 

 

to light

 

on propane tank(s)

 

slowly.

 

 

 

 

2.

Excess flow check valve

2.

Close propane supply valve on

 

 

 

 

 

closed

 

propane tank and reopen slowly.

 

 

 

 

3.

Air in gas line

3.

Allow several minutes to purge

 

 

 

 

 

 

 

air with automatic control

 

 

 

 

 

 

 

valve button depressed.

 

 

 

 

4.

Blockage in pilot orifice

4.

Replace pilot orifice.

 

 

 

 

5.

Piezo ignition system not

5.

Adjust ignitor electrode gap to

 

 

 

 

 

sparking

 

.120". Check wire lead for

 

 

 

 

 

 

 

damage. Replace piezo ignitor

 

 

 

 

 

 

 

and/or ignitor electrode as

 

 

 

 

 

 

 

necessary.

 

 

 

 

 

 

 

 

 

Pilot lights

1. Not enough warm up time

1.

Relight, hold automatic control

 

 

but goes

 

 

 

valve button in 45 seconds.

 

 

out when

2. Low gas pressure

2.

Check propane tank(s) for

 

 

automatic

 

 

 

proper gas supply.

 

 

control valve

3. Thermocouple loose or

3.

Tighten connection or replace

 

 

button

 

needs to be replaced

 

thermocouple.

 

 

is released

4.

Automatic control valve

4.

Replace automatic control

 

 

 

 

 

needs to be replaced

 

valve.

 

 

 

 

 

 

 

 

 

Burn rate

1. Main burner valve not fully

1.

Fully open main burner valve

 

 

is low

 

open

 

by turning the valve handle

 

 

 

 

 

 

 

towards HIGH position until it

 

 

 

 

 

 

 

stops.

 

 

 

 

2.

Plugged gas orifice

2.

Replace gas orifice.

 

 

 

 

3.

Low gas pressure

3.

Check gas supply; check

 

 

 

 

 

 

 

regulator output.

 

 

 

 

4.

Low fuel supply

4.

Consult propane gas supplier.

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

099684

 

 

 

 

 

 

 

Page 10
Image 10
Desa RCP80, TC80 owner manual Maintenance, Trouble Shooting

RCP80, TC80 specifications

Desa TC80 and RCP80 are innovative heating solutions designed for both residential and commercial applications. These models exemplify the latest advancements in heating technology, offering efficient and reliable performance.

The Desa TC80 is a top-of-the-line forced-air heater that delivers powerful heating capabilities. With a robust thermal output, it ensures rapid temperature rise in any space. One of its main features is its exceptional energy efficiency, made possible by its advanced heat exchanger design. The TC80 utilizes electronic ignition technology, eliminating the need for a standing pilot light, which not only enhances safety but also contributes to lower operating costs.

On the other hand, the RCP80 is a radiant ceiling panel heater that offers a unique heating experience. Unlike traditional heaters that rely on convection, the RCP80 heats objects and surfaces directly, creating a comfortable environment. This panel heater is particularly useful in spaces with high ceilings or large open areas, as it effectively spreads warmth without the common cold spots associated with conventional heating systems. Its sleek and unobtrusive design makes it an aesthetic addition to any room.

Both models come equipped with state-of-the-art control systems that allow users to adjust the temperature settings easily. The Desa TC80 features a digital thermostat for precise temperature management, while the RCP80 offers a simple dial control for user-friendly operation.

Safety is a priority in both designs. The TC80 includes a feature that automatically shuts off the heater in the event of overheating, while the RCP80 is constructed with high-quality, heat-resistant materials to prevent any risk of fire hazards.

In terms of installation, the TC80 is designed for quick and easy setup, making it accessible for homeowners and professional installers alike. The RCP80 can be mounted on ceilings or walls, providing versatile options for various room configurations.

Overall, the Desa TC80 and RCP80 represent a blend of form, function, and technology, making them ideal choices for anyone seeking reliable heating solutions. Their energy-efficient operation, advanced safety features, and modern designs set them apart in the competitive heating market, providing warmth and comfort for years to come.