Desa REM10PT Installation, Continued, Connecting To Portable Cylinder Gas Supply

Models: REM10PT

1 22
Download 22 pages 2.12 Kb
Page 6
Image 6
Installing Bottom Mounting Screw

6

INSTALLATION

Installing Heater To Wall (Cont.) Connecting to Portable Cylinder Gas Supply

INSTALLATION

Continued

Installing Bottom Mounting Screw

1.Locate bottom mounting hole. This hole is near bottom on back panel of heater (see Figure 9).

2.Mark screw location on wall.

3.Remove heater from wall.

4.If installing bottom mounting screw into hollow or solid wall, install wall anchor. Follow steps 1 through 5 under Attaching To Wall Anchor Method, page 5. If installing bottom mounting screw into wall stud, drill hole at marked location using 9/64" drill bit.

5.Replace heater on wall.

6.Insert bottom anchor screw through back panel into bottom anchor or drilled hole (see Figure 9).

7.Tighten screw until heater is firmly secured to wall. Do not over tighten.

Note: Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 9 and 10).

Figure 9 - Installing Bottom Mounting Screw

2.Connect fuel gas fitting on hose/regulator assembly to pro- pane/LP tank(s). Turn fuel gas fitting counterclockwise into threads on tank. Tighten firmly using a wrench. IMPORTANT: Position regulator so that hose leaving the regulator is in a horizontal position (see Figure 10). This places the regulator vent in the proper position to protect it from the weather.

3.Connect hose to heater inlet. Tighten firmly using a wrench. You must use the regulator supplied with heater.

4.Open propane/LP supply valve on propane/LP tank(s) slowly. Note: If not opened slowly, excess-flow check valve on pro- pane/LP tank may stop gas flow. If this happens, close pro- pane/LP supply valve and open again slowly.

5.Check all connections for leaks. Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak that must be corrected.

6.Close propane/LP supply valve.

Regulator

Propane/LP

Supply

Valve

 

Fuel Gas

 

Propane/LP

Fitting

Hose To

Tank

 

Heater

Figure 10 - Regulator Position

 

 

CONNECTING TO PORTABLE CYLINDER GAS SUPPLY

CONNECTING TO PORTABLE CYLINDER GAS SUPPLY WARNING: Review and understand the warnings in the Safety Information section, page 2. They are needed to safely operate this heater. Follow all local codes when using this heater.

Manual background WARNING: Test all gas piping and connections for leaks after installation or servicing. Never use an open flame to check for a leak. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

IMPORTANT: You must use a propane/LP gas supply cylinder that is compatible with the connection device provided with the hose and regulator.

1.Provide propane/LP supply system (see Propane/LP Supply, page 4).

Manual background Pressure

Regulator

Heater

Cabinet

Manual background Hose Fitting

Elbow

Hose To

Regulator

Figure 11 - Gas Connection

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background