Desa R200, REM200, B200 Troubleshooting, Observed Fault, Possible Cause, Remedy, ters, page

Models: REM200 B200 R200

1 16
Download 16 pages 32.88 Kb
Page 7
Image 7
TROUBLESHOOTING

OWNER’S MANUAL

TROUBLESHOOTING

Note: For additional help, visit DESA International’s Technical Service web site at www.desatech.com.

OBSERVED FAULT WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

OBSERVED FAULT

POSSIBLE CAUSE

REMEDY

Heater ignites, but flame-out control shuts off heater after a short period of time

1.

Wrong pump pressure

1.

See Pump Pressure Adjustment, page 8

2.

Dirty air output, air intake and lint

2.

See Air Output, Air Intake and Lint Fil-

 

filters

 

ters, page 8

3.

Dirty fuel filter

3.

See Fuel Filter, page 9

4.

Dirt in nozzle

4.

See Nozzle, page 10

5.

Dirty photocell lens

5.

Clean photocell lens

6.

Bad flame-out control

6.

Replace flame-out control

Heater will not ignite, but motor runs for a short period of time

1.Wrong pump pressure

2.Improper spark plug gap/position or carbon deposits across gap

3.Dirty fuel filter

4.Dirt in nozzle

5.Water in fuel tank

1.See Pump Pressure Adjustment, page 8

2.See Spark Plug, page 10

3.See Fuel Filter, page 9

4.See Nozzle, page 10

5.Drain and flush fuel tank with clean kerosene. See Storing, Transporting, or Shipping, page 6

6. Bad fuel valve

6. See Fuel Valve, page 9

 

POSSIBLE CAUSE WARNING: High voltage!

 

7.

Electronic ignitor not grounded

7.

Make sure electronic ignitor mounting

 

 

 

 

is tight

 

8.

Bad electronic ignitor

8.

Replace electronic ignitor

 

 

 

 

 

Motor does not start when heater is plugged

1.

Flame-out control not reset

1.

Press flame-out control reset button

in, fan rotates slowly or does not turn

2.

Solid state relay not allowed to reset

2.

Wait two minutes before trying to re-

 

 

 

 

 

start heater

 

3.

Binding pump rotor

3.

If fan is hard to turn, see Pump Rotor,

 

 

 

page 11

www.desatech.com

102569

7

Page 7
Image 7
Desa R200, REM200 Troubleshooting, Observed Fault, Possible Cause, Remedy, See Pump Pressure Adjustment, page, ters, page