OWNER’S MANUAL
TROUBLESHOOTING
Note: For additional help, visit DESA International’s Technical Service web site at www.desatech.com.
WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.
OBSERVED FAULT | POSSIBLE CAUSE | REMEDY |
Heater ignites, but
1. | Wrong pump pressure | 1. | See Pump Pressure Adjustment, page 8 |
2. | Dirty air output, air intake and lint | 2. | See Air Output, Air Intake and Lint Fil- |
| filters |
| ters, page 8 |
3. | Dirty fuel filter | 3. | See Fuel Filter, page 9 |
4. | Dirt in nozzle | 4. | See Nozzle, page 10 |
5. | Dirty photocell lens | 5. | Clean photocell lens |
6. | Bad | 6. | Replace |
Heater will not ignite, but motor runs for a short period of time
1.Wrong pump pressure
2.Improper spark plug gap/position or carbon deposits across gap
3.Dirty fuel filter
4.Dirt in nozzle
5.Water in fuel tank
1.See Pump Pressure Adjustment, page 8
2.See Spark Plug, page 10
3.See Fuel Filter, page 9
4.See Nozzle, page 10
5.Drain and flush fuel tank with clean kerosene. See Storing, Transporting, or Shipping, page 6
6. Bad fuel valve | 6. See Fuel Valve, page 9 |
|
WARNING: High voltage!
| 7. | Electronic ignitor not grounded | 7. | Make sure electronic ignitor mounting |
|
|
|
| is tight |
| 8. | Bad electronic ignitor | 8. | Replace electronic ignitor |
|
|
|
|
|
Motor does not start when heater is plugged | 1. | 1. | Press | |
in, fan rotates slowly or does not turn | 2. | Solid state relay not allowed to reset | 2. | Wait two minutes before trying to re- |
| ||||
|
|
|
| start heater |
| 3. | Binding pump rotor | 3. | If fan is hard to turn, see Pump Rotor, |
|
|
|
page 11
www.desatech.com
102569 | 7 |