Desa REM200, R200 Continued, Fuel Filter, Fuel Valve, WARNING High Voltage, Service Procedures

Models: REM200 B200 R200

1 16
Download 16 pages 32.88 Kb
Page 9
Image 9
Continued

OWNER’S MANUAL

SERVICE

PROCEDURES

Continued

FUEL FILTER

1.Remove side cover screws using 5/16" nut-driver.

2.Remove side cover.

3.Pull lower fuel line off the fuel valve fitting.

4.Carefully pry bushing, lower fuel line, and fuel filter out of fuel tank.

5.Wash fuel filter with clean fuel and replace in tank.

6.Attach lower fuel line to fuel valve fitting.

7.Replace side cover.

FUEL VALVE

1.Remove side cover (see Figure 10), fan guard, and upper shell (see Fig- ure 5, page 8) screws using 5/16" nut-driver.

2.Remove fan (see Fan, page 8).

3.Pull lower fuel line off the fuel valve fitting (see Figure 11).

FUEL FILTER WARNING: High Voltage

4.Disconnect red and white wires from fuel valve. (see Figure 11).

5.Using 1/4" nut driver remove 2 screws/ lockwashers holding fuel valve and bracket to lower shell (see Figure 11). Save these screws/lockwashers.

6.Using 1/4" nut driver remove 2 screws holding fuel valve to bracket. Save these screws.

7.Attach new fuel valve to bracket with 2 screws.

8.Install new fuel valve and bracket on lower shell with 2 screws/lockwashers.

9.Connect red and white wires (polarity not important). Connect upper and lower fuel lines to fuel valve (see Figure 11).

10.Replace fan, fan guard, upper shell, and side cover.

Bushing, Lower Fuel Line, and Fuel Filter

Screw

Side Cover

Fuel Valve Fitting

Figure 10 - Fuel Filter Removal

Valve

Fittings

Fuel Valve

Electrical Wires

Screw

FUEL VALVE Lockwasher

Bracket

Screw

Lower Fuel

Line

Figure 11 - Fuel Valve Replacement

Continued

102569

9

Page 9
Image 9
Desa REM200, R200, B200 owner manual Continued, Fuel Filter, Fuel Valve, WARNING High Voltage, Service Procedures