OPERATION

8

OPERATION

!WARNING

Review and understand the warnings in the Safety Information Section. They are needed to safely operate this heater. Follow all local codes when using this heater.

To Start Heater

1.Follow all ventilation and safety information.

2.Fill fuel tank with kerosene or No. 1 fuel oil.

3.Attach fuel cap.

4.Plug power cord of heater into 220 volt/60 hertz grounded outlet. Use an extension cord if needed. Use only a three-prong, grounded (earthed) exten- sion cord.

Extension Cord Wire Size Requirements

Up to 100 feet (30.5 meters) long, use 16 AWG (1.0 mm2) rated cord

101 to 200 feet (30.8 to 61 meters) long, use 14 AWG (1.5 mm2) rated cord Heater will start when power cord is plugged into outlet. If not, push in burner control reset button (see Figure 4).

Burner

Control

Reset

Button

Figure 4 - Burner Control Reset Button

To Stop Heater

1. Unplug power cord from outlet.

To Restart Heater

1.Wait 2 minutes after stopping heater.

2.Repeat steps under To Start Heater, above.