OBSERVED FAULT

POSSIBLE CAUSE

REMEDY

Heater ignites, but flame-out control shuts

1.

Wrong pump pressure

1. See Pump Pressure Adjustment, page 8

off heater after a short period of time

2.

Dirty air output, air intake and lint

2. See Air Output, Air Intake and Lint Fil-

 

 

filters

 

ters, page 8

 

3.

Dirty fuel filter

3. See Fuel Filter, page 9

 

4.

Dirt in nozzle

4. See Nozzle, page 10

 

5.

Dirty photocell lens

5.

Clean photocell lens

 

6.

Bad flame-out control

6.

Replace flame-out control

 

 

 

 

 

 

 

Heater will not ignite, but motor runs for a

1.

Wrong pump pressure

1.

See Pump Pressure Adjustment, page 8

short period of time

2.

Improper spark plug gap/position or

2.

See Spark Plug, page 10

 

 

carbon deposits across gap

 

 

 

 

3.

Dirty fuel filter

3.

See Fuel Filter, page 9

 

4.

Dirt in nozzle

4.

See Nozzle, page 10

 

5.

Water in fuel tank

5.

Drain and flush fuel tank with clean

 

 

 

 

 

kerosene. See Storing, Transporting, or

 

 

 

 

 

Shipping, page 6

 

6.

Bad fuel valve

6.

See Fuel Valve, page 9

 

 

 

 

 

 

 

 

WARNING: High voltage!

 

 

 

 

 

 

 

 

 

7.

Electronic ignitor not grounded

7.

Make sure electronic ignitor mounting

 

 

 

 

 

is tight

 

8.

Bad electronic ignitor

8.

Replace electronic ignitor

 

 

 

 

 

 

 

Motor does not start when heater is plugged

1.

Flame-out control not reset

in, fan rotates slowly or does not turn

2.

Thermostat setting is too low

 

3.

Solid state relay not allowed to reset

 

4.

Binding pump rotor

1.Press flame-out control reset button

2.Turn thermostat knob to a higher setting.

3.Wait two minutes before trying to re- start heater

4.If fan is hard to turn, see Pump Rotor, page 11

www.desatech.com