OPERATION

60,000 Btu/Hr H.S.I. Series

PORTABLE FORCED AIR HEATER

OPERATION

TO START HEATER WARNING: Review and un- derstand the warnings in the Safety Information section, page

2.They are needed to safely op- erate this heater. Follow all local codes when using this heater.

TO START HEATER

1.Follow all ventilation and safety information.

2.Fill fuel tank with kerosene or No. 1 fuel oil.

3.Attach fuel cap.

4.Plug power cord of heater into three- prong, grounded extension cord. Exten- sion cord must be at least six feet long.

Extension Cord Wire Size

Requirements

6 to 10 feet long, use 18 AWG rated cord

11 to 100 feet long, use 16 AWG rated cord

101 to 200 feet long, use 14 AWG rated cord

5.Plug extension cord into standard 120 volt/60 hertz, three-hole, grounded out- let. Note: Ignitor will preheat for five seconds then heater will start.

TO STOP HEATER

Unplug extension cord from outlet.

TO RESET HEATER

1.Unplug extension cord from outlet and wait 10 seconds (two minutes if heater has been running).

2.Plug extension cord into standard 120 volt/60 hertz, three-hole, grounded out- let. Note: Ignitor will preheat for five seconds then heater will start.

STORING,

TRANSPORTING, OR SHIPPING

Note: If shipping, transport companies re- quire fuel tanks to be empty.

1.Drain fuel tank. Drain fuel through fuel cap opening. Be sure all fuel is removed.

2.If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank, stir, and drain again. This will prevent excess debris from clogging filters dur- ing future use.

3.Replace fuel cap. Properly dispose of old and dirty fuel. Check with local auto- motive service stations that recycle oil.

4.If storing, store heater in dry place. Make sure storage place is free of dust and corrosive fumes.

IMPORTANT: Do not store kerosene over summer months for use during next heating season. Using old fuel could damage heater.

PREVENTATIVE MAINTENANCE SCHEDULE

Extension Cord Wire Size WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

Item

How Often

How To

Fuel tank

Flush every 150-200 hours of operation or

 

as needed

Air output and lint filters

Replace every 500 hours of operation or

 

once a year

Air intake filter

Wash and dry with soap an water every 500

 

hours of operation or replace as needed

Fuel filter

Clean twice a heating season or replace as

 

needed

See Storing, Transporting, or Shipping, above

See Air Output, Air Intake, and Lint Filters, page 6

See Air Output, Air Intake, and Lint Filters, page 6

See Fuel Filter, page 7

Ignitor

No maintenance required

 

Fan blades

Clean each season or as needed

See Fan, page 6

Motor

Not required/permanently lubricated

 

4

104672

Page 4
Image 4
Desa RM60 Operation, Storing Transporting, Or Shipping, Preventative Maintenance Schedule, To Start Heater, To Stop Heater