Desa SL-5326 Test And Adjustment, Specifications, Bottom of Sensor, Maximum Range, MotionMotion

Models: SL-5326

1 8
Download 8 pages 47.36 Kb
Page 3
Image 3
TEST AND ADJUSTMENT
Clamp Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When fi rst turned on, wait 1 1/2 minutes.

Turn the RANGE control to the mid position, 2-Level Lighting to OFF and the ON-TIME control to the TEST position.

MAX

 

 

 

 

B

O

ON - TIME

DUAL BRITE

 

 

O

 

 

 

T

S

 

 

MIN

 

 

 

 

TEST 1 5 2 0

OFF 3 6

DUSK TO

RANGE

 

 

MINUTES

HOUR

DAWN

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects refl ecting light may trigger the shut-off feature. Do not point other

lights at the sensor.

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on (also, the LED will fl ash several times when motion is detected).Move the sensor head up, down, or sideways to change the cover- age area. Keep the sensor at least 1" (2.5 cm) away from the lamps.

Adjust the RANGE as needed.

RANGE set too high may increase false triggering.

Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 20 minutes).

Set the 2-LEVELLighting switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn).

❒Turn on the circuit breaker and light switch. Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).

240°

8 ft.

(2.4 m)

70 ft. 100 ft.

(21 m) (30.5 m) Boosted

Maximum Range

Maximum

 

Coverage Angle

The detector is most sensitive to motion across its fi eld of view.

MotionMotion

 

Sensor

Least Sensitive

Most Sensitive

SPECIFICATIONS

Range

Up to 70 ft. (21 m); 100 ft.

 

(30.5 m) with Range Boost.

 

[varies with surrounding tem-

 

perature]

Sensing Angle

Up to 240°

Electrical Load

Up to 300 Watt Maximum

 

Incandescent [Up to 150

 

Watt maximum each lamp

 

holder.]

Power Requirements

120 VAC, 60 Hz

Operating Modes

TEST, AUTO and MANUAL

 

MODE

Time Delay

1, 5, 20 minutes

2-Level Lighting Timer ....

3, 6 hours, Dusk-to-Dawn

DESA Specialty Products reserves the right to discon- tinue products and to change specifi cations at any time without incurring any obligation to incorporate new features in products previously sold.