OPERATING HEATER
Lighting Instructions (Cont.)
To Turn Gas Off To Appliance
Manual Lighting Procedure
Optional
21
OPERATING HEATER
Continued
CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.
WARNING: Make sure the selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on automatically with selector switch in the ON position.
Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.
Pilot | Ignitor | Pilot | Ignitor | |
Electrode | ||||
Burner | ||||
Burner | Electrode |
| ||
|
|
Figure 31 - Pilot (Propane/LP) Figure 32 - Pilot (Natural)
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1.Turn control knob clockwise to the OFF position.
2a. Set selector switch in the OFF position.
2b. If Using Optional
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing one of the following:
1.Turn control knob clockwise to the PILOT position.
2.Use remote control manual OFF button.
3.Set selector switch in the OFF position.
MANUAL LIGHTING
PROCEDURE
1.Follow steps 1 through 6 under Lighting Instructions, page 20.
2.Depress control knob and light pilot with match.
3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11, Lighting Instructions, column 2, page 20.
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must be purchased sepa- rately (see Accessories, page 44). Follow instructions included with the remote control.
NOTICE: You must light the pilot before using the
1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjust- ment knob anywhere between HI and LO. Slide the selec- tor switch to the REMOTE position (see Figure 33). Note: The burner may light if
IMPORTANT: Do not leave the selector switch in the RE- MOTE or ON position when the pilot is not lit. This will drain the battery.
Flame Adjustment Knob
|
|
|
| Control |
IH |
|
| PIL | Knob in On |
ON |
| F | O | Position |
| F | N | ||
OFF |
|
| ||
| O |
| T |
|
|
| O |
| |
REMOTE |
|
|
|
|
LO |
|
|
|
|
Selector Switch in Remote Position
(Optional Remote Control)
Figure 33 - Setting the Selector switch, Control Knob, and Flame Adjustment Knob for Hand-Held Remote Operation
ON/OFF SERIES (MODEL GHRCB)
Hold the control button on the
TO LOCK press both buttons on
TO UNLOCK press both buttons together on
Control Button
Turns Burners
On and Off
Figure 34 - On/Off Hand-Held Remote Control Unit (GHRCB)
For morevisit www..com