SPECIFICATIONS

SPECIFICATIONS

 

350,000 Btu/Hr

600,000 Btu/Hr

Output Rating (Btu/Hr)

350,000

600,000

Fuel

Use only kerosene or #1 fuel oil

Fuel Tank Capacity (U.S. Gallons)

30

36

Fuel Consumption (Gallons Per Hr)

2.5

4

Electric Requirements

120V/60 Hz

120V/60 Hz

Amperage (Normal Run)

7.1

11

Motor RPM

1725

1725

Fuel Pump Pressure (PSI)

100

110

Spark Plug Gap

.075"

.075"

Weight (approx. lbs.) Dry

180

285

With Full Fuel Tank

390

550

WIRING DIAGRAM

7

5

B 350,000 Btu/HrWIRING DIAGRAM A

RELAY

WHITE

BLACK

RED

BLACK

12

FAN

SWITCH

Manual background 3

PLUG BLACK GREEN

WHITE

120V

60Hz

BLACK

THERMOSTAT BLACK B

FLAME-OUT

RESET

 

 

 

WHITE

CONTROL R

BUTTON

 

 

 

 

BLUE

RED

 

ORANGE

 

 

 

WHITE

MOTOR

 

 

 

 

 

 

 

RED

 

 

 

 

YELLOW

 

 

TERMINAL

TERMINAL

 

 

 

BOARD

BOARD

 

 

 

WHITE

 

 

 

 

 

WHITE

 

 

 

 

 

YELLOW

 

 

 

SPARK

 

RED

 

 

WHITE

PLUG

YELLOW

 

WHITE

 

 

 

 

VALVE

 

 

 

 

 

SOLENOID

 

 

 

ELECTRONIC

 

 

 

 

 

IGNITOR

 

 

 

 

 

WHITE

 

BLUE

 

 

ORANGE

PHOTOCELL

 

 

110098-01G

www.desatech.com