Firebox Installation

Continued

 

2" X 4" Stud

Drywall

 

Combustible

 

Materials

 

33°

 

6" Nom.

 

(15.2 cm)

 

12" Min.

 

(30.4 cm)

 

9" Min.

 

(22.8 cm)

Fireplace Side View

Front

3" Nom.

Face

(7.6 cm)

Fireplace Front View

1 1/2" Max.

(3.8 cm)

 

Figure 4 - Mantel Clearances to

Combustible Materials

Top View of Fireplace

 

Seal Gaps with

 

Noncombustible

Drywall

 

 

Mortar or Adhesive

4"

 

 

2 3/4" Max.

 

 

(6.98 cm)

(Approx.)

 

 

 

 

 

(10.1 cm) 33°

 

 

 

Nom.

 

 

 

 

4 3/8"

 

Combustible

 

Min.

 

Material Must

6" Nom.

(11.1 cm)

Not Overlap

 

 

Black Metal

(15.2 cm)

 

 

Front Face

Figure 5 - Mantel Clearances to Metal

Face

Framing

1.Frame the opening for the firebox using the dimensions shown in Figures 6 and 7 depending on your installation.

2.If firebox is to be installed directly on carpeting, tile (other than ceramic) or any combustible material other than wood flooring, firebox must be installed upon a metal or wood panel extending full width and depth of firebox.

 

12 3/8" Dia.

 

(31.4 cm) Outer Pipe

1" (2.5 cm) Min.

2" (5.1 cm) Min.

To Combustibles

Clearance From Outer

 

Pipes to Combustibles

 

24"

 

(61 cm)

 

12"

 

(31 cm)

21 5/16"

(54 cm)

42 5/8" (108 cm)

Figure 6 - Framing Clearances

3.Set firebox directly in front of opening and slide unit back until nailing flanges touch side framing.

4.Check the level of firebox and shim with sheet metal if necessary.

5.Before securing firebox to prepared fram- ing, ember protector (provided) must be placed between hearth extension (not supplied) and under bottom front edge of firebox to protect against glowing embers

(see Figure 8 and Hearth Extensions on page 6). If firebox is to be installed on a raised platform, a Z-type ember protector

(not supplied) must be fabricated to fit your required platform height (see Figure 7). The ember protector should be made of galvanized sheet metal (28 gauge mini- mum) to prevent corrosion.

6.Secure firebox to framing at nailing flanges located on sides of firebox (see

Figure 9, page 6).

 

 

 

 

"Z" Type

 

 

 

 

Ember Protector

 

 

 

 

(Not Supplied)

 

 

44

5

 

 

(1

 

/

 

 

 

8"

 

 

13 .

 

 

.

 

cm)

 

 

Min

53

Min

 

 

7

 

 

(136

 

8"

 

 

 

 

/

 

 

 

cm)

 

 

As

 

 

 

 

 

 

 

 

 

 

as

Required

 

 

 

 

 

 

 

 

"

 

Ceiling

 

by

 

 

 

 

 

22

3/4

)

 

 

 

 

Design

 

 

 

 

 

 

 

 

 

as

 

 

 

 

 

 

 

Clearance

 

 

 

(58

cm

 

 

 

 

 

Is

 

Long

 

Platform Must be

 

 

 

 

 

Maintain

 

 

 

 

 

 

 

ed

Solid, Flat and

 

 

 

 

 

 

 

 

Fully Supported

Figure 7 - Framing Firebox with “Z” Type

Ember Protectors

Ember

1/2"

Protector

(1.2 cm)

(Typ. 2 of 2)

Max.

 

Figure 8 - Ember Protectors

55511E

www.desatech.com

5