Firebox Installation

Continued

1/2" (1.27 cm)

 

Minimum to

 

Combustibles

 

Nailing

 

Flanges

 

Prepared

Nails or

Framing

 

Screws

Figure 9 - Nailing Flanges

Hearth Extension

A hearth extension projecting a minimum of 16" in front of and a minimum of 8" beyond each side of the firebox opening is required to protect combustible floor construction in front of firebox (see Figure 10). Fabricate a hearth extension using a material which meets the following specifications: a layer of noncom- bustible, inorganic material having a thermal conductivity of K=0.84 BTU IN/FT, HR. F (or less) at 1" thick. For example, if the material selected has a K factor of 0.25, such as glass fiber, the following formula would apply:

0.25x 1.0" = 0.30" thickness required

8"

MIN.

 

(20.

 

3cm)

 

 

36

1

 

 

 

 

 

 

 

/

 

 

 

 

 

 

2"

 

 

.

52

/ (92. MIN.

 

 

1

 

 

7cm)

 

 

 

 

2"

 

 

MIN

 

 

.MIN.

16"

 

 

(133

3cm)

 

 

 

 

 

 

 

.

 

 

 

 

 

 

(40

6cm)

 

 

 

 

 

 

 

Thermal conductivity "K" of materials can be obtained from manufacturer or supplier of noncombustible material.

If hearth extension is to be raised, a “Z” type ember protector must be used (see Figure 7, page 5, and Figure 11)

 

 

Noncombustible

 

 

Hearth

 

 

Extension

 

 

8" Max.

1

1/2" Typ.

“Z” Type Ember

Protector

 

 

Noncombustible

 

 

Hearth Extension

 

 

K” Factor

 

 

.84

1 1/2" Typ.

 

 

 

Ember Protector

Figure 11 - Raised Hearth Extension

Venting Installation

Optional Outside air Kit

The installation of an outside air kit should be performed during the rough framing of the firebox due to the nature of it’s location. Outside combustion air is accessed through and exterior wall or a vented crawl space (see Figure 12, page 7).

CAUTION: Air inlet ducts must not terminate in attic space.

The maximum height for the air vent can not exceed 3 feet below the flue gas outlet of the termination.

Avoid installing outside air eyebrow in areas where inlet opening may be blocked by snow, bushes or other obstacles. It should also be located beyond the reach of small children.

NONCOMBUSTIBLE

HEARTH EXTENSION

Figure 10 - Hearth Extension

For further details on installation of outside air kit, please refer to instructions included with air kit. For operating instructions, please refer to your owner's manual.