VENTING INSTALLATION INSTRUCTIONS

Continued

Vertical Venting

V = 40' max.

Note: Install restrictor into inner collar of fireplace as shown.

45° Elbow

Figure 24 - Vertical Venting Configuration With No Horizontal Run (Vertical Round High Wind Termination Shown)

VENTING INSTALLATION INSTRUCTIONS

15

Installation for Vertical Termination (Cont.)

High Altitude Installation

 

Parts Lists for Venting Kits and Components

 

 

 

HIGH ALTITUDE INSTALLATION

Your DESA direct-vent fireplace has been tested and approved for elevations from 0-2000 feet (USA) and elevations from 0-4500 feet (Canada) .

When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification.

When installing this fireplace at an elevation above 4500 feet (in Canada), check with local authorities.

Consult your local gas company to help determine the proper orifice for your location.

For assistance with any high altitude installation contact DESA’s Customer Service Department at 1-866-672-6040.

PARTS LISTS FOR VENTING KITS AND COMPONENTS

DESA (5/8") Pipe & Vent Kits

Number Description

P58-6 6" Section Double Wall Pipe, Galvanized

P58-12 12" Section Double Wall Pipe, Galvanized

P58-24 24" Section Double Wall Pipe, Galvanized

P58-36 36" Section Double Wall Pipe, Galvanized

P58-48 48" Section Double Wall Pipe, Galvanized PA58-712 Adjustable 7"-12" Section Double Wall Pipe, Galva-

nized

FPA58-6 6" Duravent Collar to FMI Pipe Adaptor (6" Collar/Pipe Section)

DPA58-6 6" FMI Collar to Pipe Duravent Adaptor (6" Collar/Pipe Section)

E58-45 45 deg. Elbow, Galvanized

E58-90 90 deg. Elbow, Galvanized

FSE58-45 45 deg. Starter Elbow, Galvanized (Duravent Collar to FMI Pipe)

DSE58-45 45 deg. Starter Elbow, Galvanized (FMI Collar to Duravent Pipe)

VKG-58 Ground Floor Vent Kit VKB-58 Basement Vent Kit VKS-58 Snorkel Vent Kit VKR-58 Roof Vent Kit VKC-58 Corner Vent Kit

HTK Horizontal Round Termination Kit

HT-58 Horizontal Round Termination, Galvanized HTKS-47 Horizontal Square Termination Kit

Includes: Square Termination, Wall Firestop, and 45° Elbow

HTS-58 Horizontal Square Termination, Galvanized

VT-58 Vertical Round Termination, Galvanized ST-58-14 14" Snorkel Termination, Galvanized ST-58-36 36" Snorkel Termination, Galvanized

SC-58 Storm Collar, Galvanized

WF-58 Wall Firestop, Galvanized

RF-58-6 Roof Flashing - 0 to 6/12 Pitch, Galvanized

For morevisit www..com

111253-01D

Page 15
Image 15
Desa V36EP-A Series, VV36EPB(1) Series High Altitude Installation, Parts Lists for Venting Kits and Components