FIREPLACE INSTALLATION
Installing Gas Piping to Fireplace Location (Cont.) Connecting Fireplace To Gas Supply
19
FIREPLACE INSTALLATION
Continued
We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 31. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas con- trols. If sediment trap/drip leg is not installed or is installed wrong, fireplace may not run properly.
CSA
Equipment Shutoff Valve
with 1/8" NPT Tap*
CONNECTING FIREPLACE TO GAS SUPPLY
Installation Items Needed
•5/16" hex socket wrench or
•sealant (resistant to propane/LP gas, not provided)
1.Open lower louver door panel by gently pulling forward.
2.Route flexible gas line (provided by installer) from equipment shutoff valve to fireplace. Route flexible gas supply line through one of the access holes on side of fireplace.
3.Attach flexible gas line from gas supply to control valve (see Figure 32).
4.Check all gas connections for leaks. See Checking Gas Con- nections.
Approved Flexible
Gas Line
3" Minimum
Natural - From Gas Meter (5.5" W.C. to 10.5"
W.C. Pressure)
Propane/LP From External Regulator (11" W.C. to 14" W.C. Pressure)
| Red Surface Indicates |
Equipment | For Propane/LP Use Only |
Flexible Gas Line | |
Shutoff Valve | Do NOT Kink |
1/2" NPT Incoming |
|
|
Gas Line | Inlet Pressure Tap | Outlet Pressure Tap |
|
Cap Pipe Nipple Tee Joint
Note: Wire Connections Not Shown for Clarity
Figure 31 - Gas Connection
Sediment Trap/Drip Leg
Figure 32 - Connecting Flexible Gas Line to Electronic Valve
*The CSA
For morevisit www..com