Venting Installation
Continued
CORNER INSTALLATION |
|
| Required |
| |
Recommended Applications: | Vertical (V) | Vertical Pipe | Horizontal (H) | ||
• Corner ground floor installation | *43 1/2" min. | None | 30" max. | ||
• Ground floor installation where pipe vents | 54 1/2" min. | 1 ft. | 48" max. | ||
horizontally through wall (over 12" horizon- | 66 1/2" min. | 2 ft. | 60" max. | ||
tal pipe) |
| 78 1/2" min. | 3 ft. | 84" max. | |
• Basement installation where one foot clear- | 90 1/2" min. | 4 ft. | 20' max. | ||
ance from ground to termination is possible | * Ground Floor Corner Venting |
| |||
Not to Exceed (H) Limits | 90° Elbow | Not to Exceed |
| ||
|
| ||||
Square | As Required | (H) Limits | Square | ||
Termination |
|
| Termination | ||
for (V), See | 90° Elbow | ||||
|
| ||||
| Chart for |
|
|
| |
| Pipe Section |
|
|
| |
| Required |
|
|
| |
Wall |
|
| Wall | 12" Min. | |
Firestop |
|
| Firestop | ||
|
|
| |||
45° Elbow |
|
|
|
| |
|
|
| 45° Elbow |
|
Figure 15 - Horizontal Termination Configuration for Corner Installation Using One
90° Elbow
SNORKEL TERMINATION INSTALLATION
Recommended Applications:
•Installations requiring a vertical rise on building exterior
•Any installation using snorkel termination to achieve one foot above ground
Snorkel terminations are available for installations requiring a vertical rise on the exterior of the building. If installing snorkel termination below grade, you must provide proper drainage to prevent water from entering snorkel termination (see Figure 16). Do not back fill around snorkel termination.
| Snorkel Termination | Wall |
|
| Firestop |
Snorkel Termination | 90° Elbow |
12" Min.
12" Min.
12"
Min.
45° Elbow
Adequate
Drainage
Figure 16 - Snorkel Termination Configurations for Below Ground Installation
www.desatech.com | 13 |