Fireplace Installation

Continued

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Figure 34, page 23).

2.Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natural gas fireplace.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to gas valve (see Figure 35 or Figure 36, page 23). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

5.Light fireplace (see Operation, page 27). Check all other internal joints for leaks.

6.Turn off fireplace (see To Turn Off Gas to Appliance, page 28).

Installing optional wall Mount Switch - gwmS2

1.Connect one terminal of 25 ft. wire for wall switch to TPTH terminal on valve. Connect remaining wire terminal to TH terminal on valve. Make sure that wire ter- minals are in positions on unit as pictured in Figure 37. If wires are not connected as shown switch will not work.

2.Route 25 ft. wire through openings pro- vided on sides of burner system to a con- venient location to mount your switch.

3.Connect one bare wire end to each termi- nal of GWMS2 wall switch.

4.Install wall switch and cover in the wall.

To Wall Switch

Accessory

Installing Optional Wireless hand-held REMOTE CONTROL HRC100 and HRC200 Series

NOTICE: Use only alkaline batteries (not included).

Installing Remote Receiver

1.Open bottom louver and locate switch bracket on the right.

2.Unscrew switch bracket. Lean bracket forward so you are able to access back of remote receiver.

3.Locate battery clip mounted on back of receiver. Slide a 9-volt alkaline battery (not included) through clip (see Figure 38).

4.Attach terminal wires to battery.

5.Connect wires from receiver to TH and TPTH to control valve (see Figure 39).

6.Replace switch bracket.

Receiver

9-Volt Alkaline Battery

Terminal

Wires

Battery Clip

Figure 38 - Attaching Alkaline Battery to

Receiver

To Optional

Remote

Accessory

Figure 39 - Control Valve Terminals

Figure 37 - Connecting Wall Switch to

Control Valve

24

www.desatech.com

116200-01L