TROUBLESHOOTING

Continued

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

Heater produces a whistling 1.

Turning gas control knob to

noise when burner is lit

HI position when burner is

 

cold

2.

Air in gas line

3. Dirty or partially clogged burner orifice

1.Turn gas control knob to LO position and let warm up for a minute

2.Operate burner until air is removed from line. Have gas line checked by local propane/LP or natural gas company

3.Clean burner (see Cleaning and Maintenance, page 31) or replace burner orifice

Glass soots

1.

Debris around burner air

1.

Inspect opening at base

 

 

mixer

 

of burner by removing

 

 

 

 

log/grate assembly to

 

 

 

 

see that it is NOT packed

 

 

 

 

with any type of material

 

 

 

 

[see Installing Brick Liner

 

 

 

 

Models BL36DA(SA) and

 

 

 

 

BL36DHA(SA), page 26 for

 

 

 

 

log/grate removal]

 

2.

Improper vent configura-

2.

Check vent configuration

 

 

tion

 

specifications (see Venting

 

 

 

 

Installation, page 9)

 

 

 

 

 

Fireplace produces a clicking/

1.

Metal expanding while

1.

This is normal. If noise is

ticking noise just after burners

 

heating or contracting

 

excessive, contact qualified

are lit or shut off

 

while cooling

 

service person

 

 

 

 

 

Remote does not function

1.

Battery is not installed or

1.

Replace 9-volt batteries

 

 

battery power is low

 

in receiver and hand-held

 

 

 

 

remote control

Dark residue on logs or inside of fireplace

1.Air holes at burner inlet blocked

2. B u r n e r f l a m e h o l e s blocked

3.Improper venting or exces- sive blockage

4.Excessive amounts of embers and pan material

1.Clean out air holes at burn- er inlets. Periodically repeat as needed

2.Remove blockage or re- place burner

3.Have vent system inspect- ed, including termination cap. Remove any restric- tions or obstruction

4.Clear excess embers until a minimum gap of 1/2" remains under the grate