UNVENTED PROPANE/LP GAS FIREPLACE

INSTALLATION

Continued

CHECKING GAS

CONNECTIONS

WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Fig- ure 22).

2.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

3.Check all joints from propane/LP sup- ply to equipment shutoff valve (see Fig- ure 23). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

4.Correct all leaks at once.

Open

Equipment

Shutoff

Valve

Closed

Figure 22 - Equipment Shutoff Valve

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Fig- ure 22).

2.Open propane/LP supply tank valve.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Fig- ure 23). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

6.Light fireplace (see Operating Fire- place, pages 14 through 16). Check all other internal joints for leaks.

7.Turn off fireplace (see To Turn Off Gas to Appliance, page 15).

1.Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas sup- ply piping system. Pressures in excess of 1/2 psig will damage fireplace gas regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was con- nected.

3.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

6.Reconnect fireplace and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.

Equipment Shutoff Valve

,,,,,,,,QQQQQQQQ¢¢¢¢¢¢¢¢,Q¢

Gas Control Valve

Figure 23 - Checking Gas Joints

Propane/LP Supply Tank

12

104637

Page 12
Image 12
Desa VCGF30PR installation manual Checking GAS Connections, Pressure Testing Gas Supply Piping System

VCGF30PR specifications

The Desa VCGF30PR is an advanced gas fireplace designed for both aesthetic appeal and functional efficiency. This model stands out in the market for its combination of modern technology, sleek design, and user-friendly features, making it an excellent choice for homeowners seeking an elegant heating solution.

One of the standout features of the VCGF30PR is its impressive heating capacity. Designed to warm spaces effectively, it can heat an area of around 1,200 square feet, making it ideal for living rooms, dens, and other large spaces in the home. The fireplace operates on natural gas or propane, providing flexibility depending on the homeowner's needs and preferences.

The unit boasts a stunning ceramic glass front, allowing for a clear view of the flames while minimizing heat loss. This design not only enhances the aesthetic appeal of the fireplace but also aids in energy efficiency. The use of advanced technology ensures that the flames are realistic and comforting, creating the perfect ambiance for any occasion.

One of the significant technological advancements in the VCGF30PR is its electronic ignition system. This feature enables quick and hassle-free startups with just the push of a button. The unit is also equipped with a built-in blower, which helps circulate warm air throughout the room, enhancing heating efficiency and comfort.

Safety is a priority with the Desa VCGF30PR. The fireplace includes a built-in safety shut-off valve that automatically cuts the gas supply in case of any irregularities, providing peace of mind for users. Additionally, it features a thermostat control, allowing homeowners to set their desired temperature for optimal comfort without constant monitoring.

The VCGF30PR also incorporates easy maintenance features. Its design allows for straightforward cleaning and upkeep, ensuring that it remains a captivating focal point in any home for years to come. The variety of finish options available—such as brushed nickel, black, or traditional bronze—allows homeowners to customize the look of their fireplace to match their interior décor.

In conclusion, the Desa VCGF30PR gas fireplace combines modern technology, safety features, and beautiful design elements, making it a remarkable addition to any home. With its efficient heating capabilities, user-friendly operation, and elegant appearance, it promises both comfort and style for years to come.