Desa VGL24NR, VGL24PR installation manual Cleaning And Maintenance, Logs, Main Burner

Models: VGL24PR VGL24NR

1 30
Download 30 pages 20.88 Kb
Page 19
Image 19
CLEANING AND

CLEANING AND MAINTENANCE

Cleaning Burner Injector Holder and Pilot Air Inlet Hole

Logs

Main Burner

19

CLEANING AND

MAINTENANCE

LOGS WARNING: Turn off heater and let cool before cleaning.

Manual background CAUTION: You must keep control areas, burner, and circulating air passageways of heater clean. In- spect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to exces- sive lint from carpeting, bedding material, pet hair, etc.

Manual background WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in soot- ing and property damage.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes in rear burner for dust and dirt (see Figure 36).

3.Blow air through the holes in the burner.

4.Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 37). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Primary Air

Inlet Holes

Injector

 

Holder

Burner Tube

Figure 36 - Injector Holder On Outlet Burner Tube

Pilot Air

Holes in Burner

Inlet Hole

Pilot

Assembly

 

Figure 37 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to Installing Logs, pages 14 and 15, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage, blocked burner flame holes will create soot.

For moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual background

111640-01B