Desa VGP30 Technical Service, Service Hints, Specifications, When gas pressure is too low

Models: VGP30

1 28
Download 28 pages 35.63 Kb
Page 21
Image 21
TECHNICAL

TECHNICAL

SERVICE

SPECIFICATIONS

SERVICE

HINTS

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.

B.T.U (Variable)

15,000/30,000

Type Gas

Propane Only

Ignition

Piezo

Pressure Regulator Setting

8" W.C.

Inlet Gas Pressure (inches of water)

 

Maximum

14"

Minimum

11"

Dimensions, Inches (H x W x D)

 

Heater

23.5 x 25.9 x 8.0

Carton

25.8 x 28.7 x 10.1

Weight (pounds)

 

Heater

30

Shipping

35

When gas pressure is too low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

propane gas supply may be low

When gas quality is bad

pilot will not stay lit

burner will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.

21

Page 21
Image 21
Desa VGP30 Technical Service, Service Hints, Specifications, When gas pressure is too low, When gas quality is bad