Desa (V)K42P SERIES Vertical Termination Configurations, Venting with One 90 Elbow

Models: (V)K42P SERIES

1 40
Download 40 pages 37.84 Kb
Page 14
Image 14

14

VENTING INSTALLATION INSTRUCTIONS

Installation for Vertical Termination (Cont.)

VENTING INSTALLATION INSTRUCTIONS

Continued

Vertical Termination Configurations

Figures 21 through 24 show four different configurations for verti- cal termination.

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H1) +

 

Horizontal (H2)

5' min.

2' max.

 

6' min.

4' max.

 

7' min.

6' max.

Note: Install

8' min.

8' max.

restrictor into

20' max.

8' max.

inner collar of

 

 

 

fireplace as

45° Elbow

shown.

 

Venting with One 90° Elbow

Vertical (V)

Horizontal (H)

5' min.

2' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

20' max.

8' max.

45° Elbow

Note: Install restrictor

into inner collar of

 

 

fireplace as shown.

Figure 22 - Vertical Venting Configuration Using One 90° Elbow

(Vertical Round High Wind Termination Shown)

Venting with Two 90° Elbows

Vertical (V1)

Horizontal (H)

5' min.

6' max.

6' min.

12' max.

7' min.

18' max.

8' min.

20' max.

Figure 21 - Vertical Venting Configuration Using Two 90° Elbows with Two Horizontal Runs (Vertical Round High Wind Termination Shown)

Note: Install restrictor into inner collar of fireplace as shown.

45° Elbow

Note: Vertical (V1) + Vertical (V2) = 40' max.

Figure 23 - Vertical Venting Configuration Using Two 90° Elbows

(Vertical Round High Wind Termination Shown)

For..com

111921-01D

Page 14
Image 14
Desa (V)K42P SERIES installation manual Vertical Termination Configurations, Venting with One 90 Elbow