Desa VMH10TP Trouble- Shooting, Continued, Observed, Possible, Remedy, Problem, Cause

Models: VMH10TP

1 32
Download 32 pages 53.03 Kb
Page 26
Image 26
Manual background

TROUBLE- SHOOTING

OBSERVED

POSSIBLE

REMEDY

PROBLEM

CAUSE

 

 

 

Continued

Burner does not light

1.

Burner orifice is

after ODS/pilot is lit

 

clogged

 

2.

Burner orifice diameter

 

 

is too small

 

3.

Inlet gas pressure is

 

 

too low

1.Clean burner (see Cleaning and Mainte- nance, page 24) or replace burner orifice

2.Replace burner orifice

3.Contact local propane/ LP gas company

Delayed ignition of

1.

Manifold pressure is

burner

 

too low

 

2.

Burner orifice is

 

 

clogged

1.Contact local propane/ LP gas company

2.Clean burner (see Cleaning and Mainte- nance, page 24) or replace burner orifice

Burner backfiring

1. Burner orifice is

during combustion

clogged or damaged

2. Burner damaged

3. Low inlet gas pressure

4. Gas regulator defective

1.Clean burner (see Cleaning and Mainte- nance, page 24) or replace burner orifice

2.Replace burner pressure

3.Contact local propane/ LP gas company

4.Replace gas regulator

Slight smoke or odor

1. Residues from manu-

1. Problem will stop after a

during initial operation

facturing processes

few hours of operation

26

Fireplace produces a

1.

Air in gas line

whistling noise when

 

 

burner is lit

 

 

 

2.

Air passageways on

 

 

fireplace blocked

 

3.

Dirty or partially

 

 

clogged burner orifice

1.Operate burner until air is removed from line. Have gas line checked by local propane/LP gas company

2.Observe minimum installation clearances (see Figures 6 and 7 page 11)

3.Clean burner (see Cleaning and Mainte- nance, page 24) or replace burner orifice

103669

Page 26
Image 26
Desa VMH10TP installation manual Trouble- Shooting, Continued, Observed, Possible, Remedy, Problem, Cause