TROUBLE- SHOOTING
Continued
WARNING
WARNING ICON | G 001 |
If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating fireplace where impurities in air exist may create odors. Clean- ing supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
| OBSERVED | POSSIBLE |
|
|
|
|
|
| |
| PROBLEM | CAUSE | REMEDY | ||||||
|
|
|
|
|
|
|
|
| |
| Fireplace produces a | 1. | Metal expanding while | 1. | This is common with | ||||
| clicking/ticking noise |
| heating or contracting |
| most fireplaces. If noise | ||||
| just after burner is lit |
| while cooling |
| is excessive, contact | ||||
| or shut off |
|
|
| qualified service person | ||||
|
|
|
|
|
|
| |||
| Fireplace produces | 1. | Fireplace burning vapors | 1. | Ventilate room. Stop | ||||
| unwanted odors |
| from paint, hair spray, |
| using odor causing | ||||
|
|
| glues, etc. (See IMPOR- |
| products while fire- | ||||
|
|
| TANT statement above) |
| place is running | ||||
|
| 2. | Low fuel supply | 2. | Refill supply tank | ||||
|
| 3. | Gas leak. See Warn- | 3. | Locate and correct all | ||||
|
|
| ing statement at |
| leaks (see Checking Gas | ||||
|
|
| top of page |
| Connections, page 18) | ||||
|
|
|
|
|
|
| |||
| Fireplace shuts off in | 1. | Not enough fresh air is | 1. | Open window and/or | ||||
| use (ODS operates) |
| available |
| door for ventilation | ||||
|
| 2. | Low line pressure | 2. | Contact local propane/ | ||||
|
|
|
|
| LP gas company | ||||
|
| 3. | ODS/pilot is partially | 3. | Clean ODS/pilot (see | ||||
|
|
| clogged |
| Cleaning and Mainte- | ||||
|
|
|
|
| nance, page 24) | ||||
|
|
|
|
|
|
|
| ||
| Gas odor even when | 1. | Gas leak. See Warn- | 1. | Locate and correct all | ||||
| control knob is in |
| ing statement at |
| leaks (see Checking Gas | ||||
| OFF position |
| top of page |
| Connections, page 18) | ||||
|
| 2. | Control valve defective | 2. | Replace control valve | ||||
|
|
|
|
|
|
| |||
| Gas odor during | 1. | Foreign matter be- | 1. | Take apart gas tubing | ||||
| combustion |
| tween control valve |
| and remove foreign | ||||
|
|
| and burner |
| matter | ||||
|
| 2. | Gas leak. See Warn- | 2. | Locate and correct all | ||||
|
|
| ing statement at |
| leaks (see Checking Gas | ||||
|
|
| top of page |
| Connections, page 18) | ||||
|
|
|
|
|
| ||||
| Moisture/condensa- | 1. | Not enough combus- | 1. Refer to Air for Combus- | |||||
| tion noticed on |
| tion/ventilation air. |
| tion and Ventilation | ||||
| windows |
|
|
| requirements (page 6) | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 27 | |||
|
|
|
|
|
|
|
|
|
|
103669