TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

Fireplace produces unwanted 1.

Fireplace burning vapors from

odors

paint, hair spray, glues, etc.

 

(See IMPORTANT statement

 

above)

2.

Low fuel supply (propane/LP)

3.

Gas leak. See Warning

 

statement above

1.Ventilate room. Stop using odor causing products while fireplace is running

2.Refill supply tank

3.Locate and correct all leaks (see Checking Gas Connec- tions, page 18)

Fireplace shuts off in use (ODS

1. Not enough fresh air is avail-

1.

Open window and/or door for

operates)

 

able

 

ventilation

 

2.

Low line pressure

2.

Contact local propane/LP or

 

 

 

 

natural gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning

 

 

 

 

and Maintenance, page 22)

 

 

 

 

Gas odor even when control

1. Gas leak. See Warning

1.

Locate and correct all leaks

knob is in OFF position

 

statement above

 

(see Checking Gas Connec-

 

 

 

 

tions, page 18)

 

2.

Control valve defective

2.

Replace control valve

Gas odor during combustion

1.

Foreign matter between con-

 

 

trol valve and burner

 

2.

Gas leak. See Warning

 

 

statement above

1.Take apart gas tubing and re- move foreign matter

2.Locate and correct all leaks (see Checking Gas Connec- tions, page 18)

Moisture/condensation noticed

1. Not enough combustion/ven-

1. Refer to Air for Combustion

on windows

tilation air

and Ventilation requirements

 

 

(page 6)

26

www.desatech.com

113111-01B

Page 26
Image 26
Desa VMH26TPC, VMH26TNC installation manual Gas leak. See Warning, Statement above