Assembling Hood

ASSEMBLY

Continued

5.Reattach screen by placing the notches in the screen frame over the shoulder screws and pushing down.

Assembling Hood

1.Locate four black phillips sheet metal screws from the hardware packet.

2.Rotate hood as shown in Figure 3. Make sure hood tabs point toward fireplace.

3.Insert hood tabs between baffle and louvers (see Figure 3).

4.Gently rotate hood to upright position. Make sure hood tabs are behind louvers and hood is resting on firebox top (see Figure 3).

5.Align screw holes on hood with screw holes on firebox top.

6.Insert screws as shown in Figure 3. Tighten screws firmly.

Figure 3 - Assembling HoodPROVIDING ADEQUATE Louver

Hood Tabs

Hood

Hood Tab

 

Baffle

Sheet Metal

Screw

Firebox Top

Figure 3 - Assembling Hood

AIR FOR COMBUSTION

AND VENTILATION

Unusually Tight Construction WARNING: This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombustionandven- tilation air. Read the following in- structions to insure proper fresh air for this and other fuel-burning appliances in your home.

Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy effi- cient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.

PROVIDING ADEQUATE

VENTILATION

The following are excerpts from National Fuel Gas Code,ANSI Z223.1/ NFPA 54, Section 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three fol- lowing ventilation classifications:

1.Unusually Tight Construction

2.Unconfined Space

3.Confined Space

The information on pages 6 through 8 will help you classify your space and provide adequate ven- tilation.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough fresh air for combustion and ven- tilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

6

www.desatech.com

113111-01B

Page 6
Image 6
Desa VMH26TPC, VMH26TNC Continued, Providing Adequate Ventilation, Assembling Hood, Unusually Tight Construction