SPECIFICATIONS

20

SPECIFICATIONS REPLACEMENT PARTS SERVICE HINTS TECHNICAL SERVICE

SPECIFICATIONS

 

RFN30TA

RFP30TA

 

VMH3000TNA

VMH3000TPA

BTU (Variable)

15,000/30,000

15,000/30,000

Type Gas

Natural Only

Propane/LP Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

3" W.C.

8" W.C.

Inlet Gas Pressure (in. of water) *

 

 

Maximum

10.5"

14"

Minimum

5"

11"

Dimensions, Inches (H x W x D)**

 

 

Heater

23.75 x 25.9 x 8.5

23.75 x 25.9 x 8.5

Carton

26 x 27.75 x 10.25

26 x 27.75 x 10.25

Weight (pounds)

 

 

Heater

29

29

Shipping

35

35

*For purposes of input adjustment **Measurement includes knobs and hood

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Cen- tral (see page 24) or call DESA International’s Technical Service Department at 1-866-672-6040.

When calling DESA International, have ready:

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Cen- tral (see page 24) or call DESA International at 1-866-672-6040 for referral information.

When calling DESA International, have ready:

model number of your heater

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

You may feel your gas pressure is too low. If so, contact your local natural gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-866-672-6040.

You can also visit DESA International’s technical service web site at www.desatech.com.

REPLACEMENT PARTSPARTS UNDER WARRANTYPARTS NOT UNDER WARRANTYSERVICE HINTSWhen Gas Pressure Is Too LowForTECHNICAL SERVICEManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

109889

Page 20
Image 20
Desa VMH3000TPA Specifications, Replacement Parts, Service Hints, Technical Service, Parts Under Warranty