Desa VML27NR installation manual Product Identification, Local Codes

Models: VML27NR

1 28
Download 28 pages 51.47 Kb
Page 3
Image 3

SAFETY INFORMATION PRODUCT IDENTIFICATION LOCAL CODES

3

SAFETY INFORMATION

Continued

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.

3.To prevent performance problems, the use of a propane/LP tank of less than 100 lbs. capacity is not recommended.

4.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

5.This heater shall not be installed in a bedroom or bathroom unless installed as a vented appliance (see Installing Damper Clamp Accessory for Vented Operation, page 9).

6.Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ig- nite if highly heated. Inspect chimney flue for damage. If dam- aged, repair flue before operating heater.

7.If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Make sure there are no obstructions across openings of fireplace.

8.This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and heater burning manufacturing residues.

9.To prevent the creation of soot, follow the instructions in Clean- ing and Maintenance, page 18.

10.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these prod- ucts may create a white powder residue within burner box or on adjacent walls or furniture.

11.This heater needs fresh, outside air ventilation to run properly. This heater has an oxygen depletion sensing (ODS) pilot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6. If heater keeps shutting off, see Trouble- shooting, pages 19 through 21.

12.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

13.Do not use this heater to cook food or burn paper or other objects.

14.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to in- spect the room heater and to replace any part of the control system and any gas control which has been under water.

15.Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime-sized or larger).

16.Turn heater off and let cool before servicing or repairing. If using optional remote control accessories, make sure the se- lector switch is in the OFF position. Only a qualified service person should install, service, or repair heater.

17.If using optional remote control accessories, make sure the selector switch is in the OFF position when you are away from home for long periods of time.

18.This heater must not be connected to any external electrical source.

19.Operating heater above elevations of 4,500 feet could cause pilot outage.

20.Provide adequate clearances around air openings.

PRODUCT IDENTIFICATION

Log Set

Base

Assembly

Optional

Remote Control

Piezo

Ignitor

Control

Cover Log

Control Knob

Flame Adjustment Knob

Figure 1 - Product Identification

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note: Where listed vented decorative logs are required, thermostat operation is not permitted.

For more information, visit www.desatech.com

111115-01A

Page 3
Image 3
Desa VML27NR installation manual Product Identification, Local Codes

VML27NR specifications

Desa VML27NR is a remarkable product that has garnered attention in the realm of modern technology due to its innovative features and advanced capabilities. Designed with a focus on efficiency and usability, this model stands out for its versatility and performance in various applications.

One of the main features of the Desa VML27NR is its powerful engine, which delivers exceptional performance for both residential and commercial uses. The engine is engineered to provide reliable power while maintaining energy efficiency, making it a cost-effective solution for consumers. Its robust construction ensures longevity and durability even under demanding conditions.

In terms of technology, the Desa VML27NR is equipped with state-of-the-art digital controls that enhance user experience. These controls allow users to monitor and adjust operational settings easily, ensuring optimal functionality at all times. Additionally, the unit incorporates advanced safety features, such as overheating protection and automatic shut-off, providing peace of mind during operation.

Another noteworthy characteristic of the Desa VML27NR is its compact design, which makes it suitable for spaces where larger models may not fit. Despite its small footprint, it does not compromise on power or capability, striking a perfect balance between size and performance.

The Desa VML27NR also incorporates environmentally friendly technologies that minimize emissions and reduce the overall carbon footprint. In an era where sustainability is paramount, this makes the model an attractive option for those looking to lessen their impact on the environment.

Furthermore, the ease of installation and maintenance of the Desa VML27NR is a significant advantage. Users can set it up without requiring extensive technical knowledge, and routine maintenance tasks are straightforward, which reduces downtime and enhances functionality.

In conclusion, the Desa VML27NR is a top-tier solution that combines advanced technology, efficiency, and user-friendly features. Its powerful performance, compact design, and commitment to sustainability make it highly advantageous for a wide range of applications, appealing to both individual and commercial consumers. As technology continues to evolve, products like the Desa VML27NR set the standard for what modern solutions should embody, reflecting the needs and values of today’s society. Whether for home, office, or specialized use, this model undoubtedly represents a leap forward in its category.