Desa VN6C, VN10 installation manual Troubleshooting

Models: VN6C VN10

1 20
Download 20 pages 41.2 Kb
Page 13
Image 13

OWNER’S MANUAL

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner(s) does not light after ODS/pilot is

1.

Burner orifice(s) is clogged

1.

Clean burner orifice(s) (see Cleaning

lit

 

 

 

and Maintenance, page 11) or replace

 

 

 

 

burner orifice(s)

 

2.

Burner orifice(s) diameter is too small

2.

Replace burner orifice(s)

 

3.

Inlet gas pressure is too low

3.

Contact local natural gas company

 

 

 

 

 

Delayed ignition of burner(s)

1.

Manifold pressure is too low

1.

Contact local natural gas company

 

2.

Burner orifice(s) is clogged

2.

Clean burner orifice(s) (see Cleaning

 

 

 

 

and Maintenance, page 11) or replace

 

 

 

 

burner orifice(s)

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice(s) is clogged or damaged

1.

Clean burner orifice(s) (see Cleaning

 

 

 

 

and Maintenance, page 11) or replace

 

 

 

 

burner orifice(s)

 

2.

Inlet gas pressure is too low

2.

Contact local natural gas company

 

3.

Burner damaged

3.

Replace burner

 

4.

Gas regulator defective

4.

Replace gas regulator

 

 

 

 

 

Burner plaque(s) does not glow

1.

Plaque damaged

1.

Replace burner

 

2.

Inlet gas pressure is too low

2.

Contact local natural gas company

 

3.

Control knob set between locked posi-

3.

Turn control knob until it locks at de-

 

 

tions

 

sired setting

 

 

 

 

 

Slight smoke or odor during initial opera-

1.

Residues from manufacturing processes

1.

Problem will stop after a few hours of

tion

 

 

 

operation

 

 

 

 

 

Heater produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most heaters. If noise is excessive, contact qualified ser- vice person

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

101851

13

Page 13
Image 13
Desa VN6C, VN10 installation manual Troubleshooting