You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.

BTU (Variable)

5,000/10,000

Type Gas

Natural Only

Ignition

Piezo

Pressure Regulator Setting

3" W.C.

Inlet Gas Pressure (inches of water)

 

Maximum

10.5"

Minimum

4"

Dimensions, Inches (H x W x D)

 

Heater

20 1/2 x 13 1/2 x 5

Carton

25 x 16 11/16 x 7 1/2

Weight (pounds)

 

Heater

13.5

Shipping

16.5

When gas pressure is too low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

When gas quality is bad

pilot will not stay lit

burner will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.