CLEANING AND MAINTENANCE

CLEANING AND MAINTENANCE

TROUBLE-

SHOOTING

Note: All troubleshooting items are listed in order of operation.

26

ODS/PILOT AND BURNER ORIFICE WARNING

Turn off heater and let cool before cleaning.

CABINET CAUTION

You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.

ODS/PILOT AND BURNER ORIFICE

• Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

Manual background WARNING

Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.

Manual background CAUTION

Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

When ignitor button is

1.

Ignitor electrode posi-

1.

Replace ignitor.

pressed in, there is no

 

tioned wrong.

 

 

spark at ODS/pilot.

2.

Ignitor electrode broken.

2.

Replace ignitor.

 

3.

Ignitor electrode not

3.

Reconnect ignitor cable.

 

 

connected to ignitor

 

 

 

 

cable.

 

 

 

4.

Ignitor cable pinched or

4.

Free ignitor cable if

 

 

wet.

 

pinched by any metal or

 

 

 

 

tubing. Keep ignitor cable

 

 

 

 

dry.

 

5.

Broken ignitor cable.

5.

Replace ignitor cable.

 

6.

Bad piezo ignitor.

6.

Replace control valve

 

 

 

 

(piezo is part of control

 

 

 

 

valve).

 

7.

Piezo ignitor nut is loose.

7.

Tighten nut holding piezo

 

 

 

 

ignitor. Nut is located

 

 

 

 

inside heater cabinet at

 

 

 

 

top.

101822