Desa VN3000D, VN1800ITA Trouble- Shooting, Continued, Observed, Possible, Remedy, Problem, Cause

Models: VN3000D VN2550ITA VN1800ITA VN1800D

1 40
Download 40 pages 11.46 Kb
Page 27
Image 27
TROUBLE- SHOOTING

TROUBLE- SHOOTING

Continued

OBSERVED

POSSIBLE

REMEDY

PROBLEM

CAUSE

 

 

 

 

 

When ignitor button is

1.

Gas supply turned off or

1.

Turn on gas supply or

pressed in, there is a

 

manual shutoff valve

 

open manual shutoff

spark at ODS/pilot but

 

closed.

 

valve.

no ignition.

2.

Control knob not fully

2.

Fully press in control

 

 

pressed in while pressing

 

knob while pressing igni-

 

 

ignitor button (non-

 

tor button (non-thermo-

 

 

thermostat models only).

 

stat models only).

 

 

Thermostat control knob

 

Fully press in thermostat

 

 

not fully pressed in while

 

control knob while press-

 

 

pressing ignitor button

 

ing ignitor button (ther-

 

 

(thermostat models only).

 

mostat models only).

 

3.

Air in gas lines when

3.

Continue holding down

 

 

installed.

 

control knob. Repeat

 

 

 

 

igniting operation until

 

 

 

 

air is removed.

 

4.

ODS/pilot is clogged.

4.

Clean ODS/pilot (see

 

 

 

 

Cleaning and Mainte-

 

 

 

 

nance, page 26) or

 

 

 

 

replace ODS/pilot

 

 

 

 

assembly.

 

5.

Gas regulator setting is

5.

Replace gas regulator.

 

 

not correct.

 

 

 

6.

Thermostat control knob

6.

Turn thermostat control

 

 

not in pilot position.

 

knob to pilot position.

ODS/pilot lights but

1.

Control knob not fully

flame goes out when

 

pressed in.

control knob is

2.

Control knob not pressed

released

 

in long enough.

 

3.

Manual shutoff valve not

 

 

fully open.

 

4.

Thermocouple connection

 

 

loose at control valve.

 

5.

Pilot flame not touching

 

 

thermocouple, which

 

 

allows thermocouple to

 

 

cool, causing pilot flame

 

 

to go out. This problem

 

 

could be caused by one or

 

 

both of the following:

 

 

A) Low gas pressure

 

 

B) Dirty or partially

 

 

clogged ODS/pilot

 

6.

Thermocouple damaged.

 

7.

Control valve damaged.

 

8.

Safety interlock system

 

 

has been triggered

 

 

(thermostat models only).

1.Press in control knob fully.

2.After ODS/pilot lights, keep control knob pressed in 30 seconds.

3.Fully open manual shut- off valve.

4.Hand tighten until snug, then tighten 1/4 turn more.

5.A) Contact local natural gas company.

B)Clean ODS/pilot (see Cleaning and Mainte- nance, page 26) or replace ODS/pilot assembly.

6.Replace thermocouple.

7.Replace control valve.

8.Wait one minute for safety interlock system to reset. Repeat ignition operation.

Continued

101822

27

Page 27
Image 27
Desa VN3000D, VN1800ITA Trouble- Shooting, Continued, Observed, Possible, Remedy, Problem, Cause, Cleaning and Mainte