Desa VP22ITA, VN18A Continued, Lighting Instructions, Ignitor Button, Control Knob, Pilot, VP16TA

Models: VN30TA VP16ITA VN18TA VP16A VP22ITA VP26A VP26TA VN30A VP16TA VN18A

1 36
Download 36 pages 38.6 Kb
Page 16
Image 16
Ignitor Button

OPERATING HEATER

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, page 15, column 2.

2.Make sure equipment shutoff valve is fully open.

3.Turn thermostat control knob clockwise Control Knob to the OFF position (see Figure 22 or 23 for your model).

4.Wait five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, page 15, column 2. If you donʼt smell gas, go to the next step.

5.Turn thermostat control knob counter-

clockwise Figure 22 - Control Knob In The OFF to the PILOT position. Press in thermostat control knob for 5 sec- onds (see Figure 22 or 23 for your model). Note: You may be running this heater for the first time after hooking up to gas supply. If so, you may need to press in thermostat control knob for 30 seconds or more. This will allow air to bleed from the gas system.

If thermostat control knob does not pop up when released, contact a qualified ser- vice person or gas supplier for repairs.

6.Keep thermostat control knob pressed in while pushing down and releasing the ignitor button. This will light pilot. If necessary, continue to press ignitor button until pilot lights.

If pilot does not light

turn thermostat control knob clockwise Position, Models VP16TA, VN18TA, to the OFF position

repeat steps 5 and 6

If pilot does not stay lit after several tries

refer to Troubleshooting, page 20

contact a qualified service person or gas supplier

Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 17.

7.Keep thermostat control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one minute before lighting pilot again.

8.Turn thermostat control knob counter-

clockwise Figure 24 - Pilot to the desired heating level. For models, VP16TA, VN18TA, VP26TA and VN30TA, the main burner should light. Set control knob to any heat level between 1 and 5 (see Figure 25). For infrastat models, the plaque directly above the pilot should light.

VP16TA CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Ignitor Button

Control Knob

 

 

F

 

F

 

O

Figure 22 - Control Knob In The OFF
Position, Models VP16TA, VN18TA,

VP26TA, & VN30TA

Plaque Control

Ignitor

Thermostat

Button

Control Knob

Knob

 

 

1

 

 

2

 

 

3

 

 

4

 

 

Figure 23 - Thermostat Control Knob In The

OFF Position, Models VP16ITA & VP22ITA

 

Thermocouple

 

Ignitor Electrode

 

 

Pilot Burner

Figure 24 - Pilot

Control

VP16TA

 

 

VP26TA

Knob

VN18TA

 

 

VN30TA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 25 - Burner Patterns

16

www.desatech.com

113052-01D

Page 16
Image 16
Desa VP22ITA Continued, Lighting Instructions, Ignitor Button, Control Knob In The OFF, Pilot, VP16TA, VP26TA, VN18TA