TECHNICAL

SERVICE

SPECIFICATIONS

SERVICE

HINTS

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.

 

VGN30B

VN2000BB

BTU (Variable)

15,000/30,000

9,000/18,000

Type Gas

Natural Only

Natural Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

3" W.C.

3" W.C.

Inlet Gas Pressure (inches of water)

 

 

Maximum

10.5"

10.5"

Minimum

4"

4"

Dimensions, Inches (H x W x D)

 

 

Heater

23.5 x 25.9 x 8.0

23.5 x 18.5 x 8.0

Carton

25.8 x 28.7 x 10.1

25.8 x 21.3 x 10.1

Weight (pounds)

 

 

Heater

30

22

Shipping

35

27

When gas pressure is too low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

When gas quality is bad

pilot will not stay lit

burner will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

100099

25

Page 25
Image 25