AIR FOR

WARNING ICONG 001 WARNING

COMBUSTION

This heater shall not be installed in a confined space unless

AND

provisions are provided for adequate combustion and ventilation

air. Read the following instructions to insure proper fresh air for

VENTILATION

this and other fuel-burning appliances in your home.

 

Today’s homes are built more energy efficient than ever. New materials, increased

 

insulation, and new construction methods help reduce heat loss in homes. Home

 

owners weather strip and caulk around windows and doors to keep the cold air out

 

and the warm air in. During heating months, home owners want their homes as

 

airtight as possible.

 

While it is good to make your home energy efficient, your home needs to breathe.

 

Fresh air must enter your home. All fuel-burning appliances need fresh air for

 

proper combustion and ventilation.

 

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from

 

the house to operate. You must provide adequate fresh air for these appliances.

 

This will insure proper venting of vented fuel-burning appliances.

 

PROVIDING ADEQUATE VENTILATION

 

The following is excerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1,

 

Section 5.3, Air for Combustion and Ventilation.

 

All spaces in homes fall into one of the three following ventilation classifications:

 

1. Unusually Tight Construction; 2. Unconfined Space; 3. Confined Space.

 

The information on pages 5 through 8 will help you classify your space and provide

 

adequate ventilation.

 

Unusually Tight Construction

 

The air that leaks around doors and windows may provide enough fresh air for

 

combustion and ventilation. However, in buildings of unusually tight construction,

 

you must provide additional fresh air.

Unusually tight construction is defined as construction where:

a.walls and ceilings exposed to the outside atmosphere have a continu- ous water vapor retarder with a rating of one perm or less with open- ings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide addi- tional fresh air. See Ventilation Air From Outdoors, page 8.

If your home does not meet all of the three criteria above, proceed to page 6.

Unconfined Space

The National Fuel Gas Code, ANSIZ223.1, 1992, Section 5.3 defines uncon- fined space as having a minimum air volume of 50 cubic feet (127 cubic cm) for each 1000 Btu/Hr input rating of all appliances in the space (cubic feet equals length x width x height of space). Include adjoining rooms only if there are doorless passageways or ventilation grills between the rooms.

Confined Space

The National Fuel Gas Code, ANSIZ223.1, 1992, Section 5.3 defines confined

 

space as having an air volume of less than 50 cubic feet (127 cubic cm) for each

 

1000 Btu/Hr input rating of all appliances in the space (cubic feet equals length

 

x width x height of space). Include adjoining rooms only if there are doorless

 

passageways or ventilation grills between the rooms.

Continued

5

101809

Page 5
Image 5
Desa CFN2800BTB, VN2800BTB installation manual AIR for Combustion, Providing Adequate Ventilation

VN2800BTB, CFN2800BTB specifications

Desa CFN2800BTB and VN2800BTB stand as premium heating solutions in the contemporary market, delivering superior warmth and user-friendly features to enhance any living environment. These models are characterized by their advanced technology, ergonomic design, and energy efficiency, making them ideal for both residential and commercial spaces.

One of the standout features of the CFN2800BTB and VN2800BTB is their innovative infrared heating technology. Unlike traditional convection heaters that warm the air, these units emit infrared rays that directly heat objects and people in the room. This not only results in faster heating but also ensures a more consistent warmth, allowing users to enjoy a comfortable ambiance even in larger spaces.

Moreover, these models boast a compact and stylish design, making them versatile for various room aesthetics. Their sleek appearance ensures that they can seamlessly blend into any decor without being obtrusive. The lightweight construction also facilitates easy relocation, allowing users to position the heater where it is most needed.

Energy efficiency is a key characteristic of the CFN2800BTB and VN2800BTB. Both units are designed to provide maximum warmth with minimal energy consumption. They feature adjustable heat settings, allowing users to customize the heating level to their needs, which not only contributes to comfort but also helps in reducing electricity bills. The built-in thermostat ensures that the heater maintains a consistent temperature, further optimizing energy use.

Safety is another paramount concern with these models. They come equipped with multiple safety features, including overheat protection and tip-over switches, which automatically turn the heater off in case of an accidental fall or overheating. This ensures peace of mind for users, particularly in homes with pets and children.

In conclusion, the Desa CFN2800BTB and VN2800BTB are exemplary heating solutions that combine modern technology with safety and efficiency. Their infrared heating capability, stylish design, and focus on user comfort make them standout products in the competitive heating appliance market. Whether for personal use or as an ideal solution for larger spaces, these models promise reliability and superior performance.