BLUE FLAME 10,000 BTU

PROPANE/LP GAS HEATER

OPERATING

HEATER

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information column 3, page 9.

2.Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

Ignitor Button

Control Knob

 

PILOT

LO

 

OFF

 

 

HI

 

IGNITOR

Figure 16 - Control Knob In The OFF Position

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation at the top of column 3, page 9. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise

C-clockwiseto the PILOT position.

Press in control knob for five (5) sec- onds (see Figure 16).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 12 through

14.Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

Ignitor Electrode

Thermocouple

Pilot Burner

Figure 17 - Pilot

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

8.Turn control knob counterclockwise

C-clockwiseto desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise Clockwise to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

1. Turn control knob clockwise Clockwise to the PILOT position.

THERMOSTAT

CONTROL

OPERATION

The thermostatic control used on these mod- els differs from standard thermostats. Stan- dard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. The thermo- stat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set tem- perature. The control knob can be set to any heat level between HI and LO. Selecting the HI setting will cause the burner to remain fully on without modulating down in most cases.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation location, room size, open air temperatures, etc.). Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 10, page 7).

2.Follow steps 1 through 5 under Light- ing Instructions.

3.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

5.Replace front panel.