®

PROPANE/LP GAS HEATER

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 19

turn heater off (see To Turn Off Gas to Appliance, page 11)

seeTroubleshooting, pages 13 through 15

Pilot Burner

Thermocouple

Figure 18 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 19 - Incorrect Pilot Flame Pattern

BURNER FLAME PATTERN

Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect burner flame pattern.

Figure 20 - Correct Burner Flame Pattern

Figure 21 - Incorrect Burner Flame Pattern

CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot for dust and dirt.

3.Blow air through the ports/slots and holes in the burner.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 22). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Pilot Air Inlet

Hole

Pilot Assembly

Figure 22 - Pilot Inlet Air Hole

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

If burner flame pattern is incorrect, as shown in Figure 21

turn heater off (see To Turn Off Gas to Appliance, page 11)

seeTroubleshooting, pages 13 through 15

ODS/PILOT AND BURNER

Exterior

• Use a soft cloth dampened with a mild

ORIFICE

• Use a vacuum cleaner, pressurized air,

soap and water mixture. Wipe the cabinet

to remove dust.

or small, soft bristled brush to clean.

 

CLEANING BURNER PILOT AIR INLET HOLE

We recommend that you clean the unit every 2,500hoursofoperationoreverythreemonths.

12

104083

Page 12
Image 12
Desa VP10TA installation manual Inspecting Burner, Cleaning and Maintenance