Image 13
Shutting Off Heater

OWNER’S MANUAL

OPERATING

HEATER

Continued

TO SELECT

HEATING LEVEL

Shutting Off Burner Only (pilot stays lit) WARNING: When running heater, set control knob at the 1, 2, 3, or 4 locked positions. Never set control knob between locked positions. Poor combustion and higher levels of carbon monox- ide may result.

Manual background CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

1.Slightly press in plaque control knob on right side of heater and turn coun-

terclockwise Manual backgroundC-clockwiseto the desired position.

IMPORTANT: Release downward pressure while turning control knob. Control knob will lock at the desired position.

2.Turn thermostat control knob on left side of heater to any setting between LO and HI. Note: When burners cycle on, or from LO to HI, a “click” will be heard. When the burners light, a “whoosh” noise will be heard.

Plaque

Control Knob VP1600ITB VP2200ITB

1

2

3 Manual background

4

1

2

3 Manual background

4

1

2

3Manual backgroundManual background

4

1

2

3 Manual background

4

Figure 19 - Burner Patterns

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn thermostat control knob clock- wise ClockwiseManual background to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn thermostat control knob clockwise Clockwise to the PILOT position.

THERMOSTAT

OPERATION

The thermostat measures the tempera- ture of air near the heater cabinet. This may not always agree with room tem- perature (depending on housing construc- tion, installation location, room size, open air temperatures, etc.). Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions, page 12.

2.With thermostat control knob pressed in, strike match. Hold match to pilot until pilot lights.

3.Keep thermostat control knob pressed in for 30 seconds after light- ing pilot. After 30 seconds, release control knob. Follow step 8 under Lighting Instructions, page 12.

104247