INFRARED PROPANE/LP GAS HEATER

OPERATING

HEATER

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information on page 11, column 3.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation page 11, column 3. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise

to the PILOT position. Press in control knob for five (5) seconds (see Figure 16).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is at- tached to the front of burner. If needed, keep pressing ignitor but- ton until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 14 through 16. Also contact a qualified service person or gas supplier for repairs. Until re- pairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure on page 13.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

8.Turn control knob counterclockwise

to desired heating level. The main burner should light. Set control knob to any heat level between HI and LOW.

CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

Ignitor Button

Control Knob

PILOT

LO

OFF

 

HI

 

IGNITOR

Figure 16 - Control Knob In The OFF Position

Ignitor Electrode

Thermocouple

Pilot Burner

Figure 17 - Pilot

Control Knob

 

VP1600TB

PILOT

 

 

 

 

 

 

 

 

OFF

 

 

 

 

HI

LO

 

 

 

 

 

 

 

 

PILOT

LO

OFF

 

HI

 

Figure 18 - Burner Patterns

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

THERMOSTAT

CONTROL

OPERATION

The thermostatic control used on these models differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set tempera- ture. The control knob can be set to any comfort level between HI and LO.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation loca- tion, room size, open air temperatures, etc.) Frequent use of your heater will let you determine your own comfort levels.

VP2600TB

12

104821

Page 12
Image 12
Desa VP2600TB Lighting Instructions, To Turn OFF GAS To Appliance, Thermostat Control Operation, Shutting Off Heater

VP1600TB, VP2600TB specifications

The Desa VP2600TB and VP1600TB are advanced ventilation and heating products designed to enhance indoor air quality and provide comfort through efficient temperature management. These models are particularly suitable for residential and commercial spaces that require reliable heating solutions without compromising on energy efficiency.

One of the standout features of both the VP2600TB and VP1600TB is their innovative heating technology. These units utilize a high-efficiency heating element that significantly reduces energy consumption while delivering consistent warmth. The VP2600TB is designed for larger spaces, offering a powerful output for effective heating, while the VP1600TB caters to smaller areas, making it an ideal choice for localized heating needs.

The thermostatic control feature allows users to set and maintain their desired temperature easily. With an integrated digital thermostat, both models ensure that users can monitor and adjust heating levels with precision, minimizing waste and optimizing comfort. This feature is particularly appealing in fluctuating weather conditions where a reliable temperature regulation system is essential.

In terms of design, both models feature a sleek and modern aesthetic that can seamlessly blend into various interior decors. The compact design of the VP1600TB makes it perfect for smaller rooms, while the robust structure of the VP2600TB ensures durability and longevity for heavy-duty use.

Another key characteristic of the Desa VP series is their safety features. Both models come equipped with a safety shut-off mechanism that activates in the event of overheating, providing peace of mind for users. Moreover, the burnished steel construction and cool-touch housing are engineered to reduce the risk of accidental burns and enhance the overall safety profile.

The VP2600TB and VP1600TB also incorporate advanced filtration systems that help improve indoor air quality. These units utilize high-capacity filters to capture dust, allergens, and other airborne particles, ensuring that the air circulated within the space is clean and healthy.

In summary, the Desa VP2600TB and VP1600TB offer a comprehensive solution for heating and ventilation needs, combining efficiency, safety, and advanced technology in one package. Their ability to adapt to various environments while maintaining energy efficiency makes them an excellent investment for anyone looking to enhance comfort within their space.