Image 20
TECHNICAL

TECHNICAL

SERVICE

SPECIFICATIONS

20

!WARNING

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

Gas odor even when

1.

Gas leak. See Warn-

1.

Locate and correct all

control knob is in OFF

 

ing statement at

 

leaks (see CHECK-

position

 

top of page

 

ING GAS CONNEC-

 

 

 

 

TIONS, page 10)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during com-

1.

Foreign matter between

1.

Take apart gas tubing

bustion

 

control valve and

 

and remove foreign mat-

 

 

burner

 

ter

 

2.

Gas leak. See Warn-

2.

Locate and correct all

 

 

ing statement at

 

leaks (see CHECKING

 

 

top of page

 

GAS CONNECTIONS,

 

 

 

 

page 10)

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.

 

VP11

VP5A

B.T.U. (Variable)

5,500/11,000

5,500

Type Gas

Propane Only

Propane Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

8" W.C.

8" W.C.

Inlet Gas Pressure (inches of water)

 

 

Maximum

14"

14"

Minimum

11"

11''

Dimensions, Inches (H x W x D)

 

 

Heater

20 1/2 x 13 1/2 x 5

20 1/2 x 13 1/2 x 5

Carton

25 x 16 11/16 x 7 1/2

25 x 16 11/16 x 7 1/2

Weight (pounds)

 

 

Heater

14

13

Shipping

17

16

Page 20