CONNECTING TO GAS SUPPLY

WARNING: This appliance re- quires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator.

WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.

CAUTION:Neverconnectheater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply.

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe 3/8" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Installation must include a equipment shutoff valve, ground joint union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13). An appliance main gas valve (equipment shutoff valve) shall be provided in an accessible location for turning on or shutting off the gas to the appliance.

IMPORTANT: Install an equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas pip- ing and/or fittings.

The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure

12.Pointing the vent down protects it from freezing rain or sleet.

Propane/LP

External

Supply Tank

Regulator

 

 

Vent

 

Pointing

 

Down

Figure 12 - External Regulator With Vent Pointing Down

3/8" NPT Pipe Nipple

Equipment

Shutoff

Valve *

From External Regulator (11" W.C. to 14" W.C. Pressure)

3" Minimum

Figure 13 - Gas Connection

Pressure

Regulator

Heater

Cabinet

Ground Joint Union

Tee Joint

 

 

 

 

 

 

 

 

Reducer

 

Test

Bushing to

 

 

Gauge

1/8" NPT

 

 

Connection*

1/8" NPT

 

 

 

Plug Tap

 

 

 

 

 

 

Tee

 

 

 

 

 

 

Joint

 

 

Pipe

 

Sediment

Nipple

 

Trap

Cap

 

 

 

*A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design-certified equipment shutoff valve from your dealer. See Accessory, page 18.

Continued

104272

9

Page 9
Image 9
Desa VP600BA installation manual Connecting to GAS Supply, External Regulator With Vent Pointing Down

VP600BA specifications

The Desa VP600BA is a highly regarded space heater known for its efficiency, versatility, and user-friendly design. Developed with the latest technology, this model prioritizes both performance and comfort, making it an ideal choice for various settings.

One of the standout features of the Desa VP600BA is its advanced heating capabilities. The heater delivers a robust output of up to 6000 BTUs, allowing it to effectively heat larger areas such as living rooms, workshops, or garages. Its efficiency is complemented by a thermostat control, which automatically regulates the temperature to ensure consistent warmth while conserving energy. This feature not only enhances comfort but also helps reduce energy costs.

In terms of design, the VP600BA boasts a compact and portable structure, making it easy to move from one room to another. This portability is especially beneficial for users who require flexibility in heating options. The heater is equipped with sturdy handles that facilitate transport, enabling users to adjust their heating based on where they need it most.

Safety is another key aspect of the Desa VP600BA. The heater features a built-in overheat shut-off mechanism, which automatically turns off the unit if it detects temperatures exceeding safe limits. This feature mitigates the risk of fires, providing peace of mind when operating the heater. Additionally, the unit is designed with a safety tip-over switch that shuts off the heater if it is accidentally knocked over.

The Desa VP600BA also integrates modern technologies such as a user-friendly control panel that allows for easy adjustments of settings. The digital display provides clear visibility of the current temperature and settings, making it intuitive to operate even for those less familiar with heating appliances.

Durability is another significant characteristic of the VP600BA. Constructed with high-quality materials, it is designed to withstand the demands of daily use. The outer casing is not only durable but also stylish, fitting seamlessly into any home or professional environment.

In conclusion, the Desa VP600BA embodies a combination of efficiency, safety, and user-friendly features. With its powerful heating capabilities, portability, and modern technological integration, it stands out as a leading choice for anyone in need of reliable heating solutions. Whether for residential or commercial use, the Desa VP600BA proves to be a dependable option for maintaining comfort during colder months.