 WARNING: If you smell gas

TROUBLESHOOTING

Continued

•Do not try to light any appliance. WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

Fireplace produces unwanted 1.

Heater burning vapors from

odors

paint, hair spray, glues, cleaners,

 

chemicals, new carpet, etc. (See

 

IMPORTANT statement above)

2.

Low fuel supply (propane/LP

 

only)

3.

Gas leak. See Warning

 

statement at top of page

1.Open window to ventilate room. Stop using odor caus- ing products while heater is running

2.Refill supply tank (propane/LP only)

3.Locate and correct all leaks (see Checking Gas Connec- tions, page 16)

Fireplace shuts off in use (ODS

1.

Not enough fresh air is avail-

1.

Open window and/or door for

operates)

 

able

 

ventilation

 

2.

Low line pressure

2.

Contact local natural or pro-

 

 

 

 

pane/LP gas company

 

3.

ODS/pilot is partially

3.

Clean ODS/pilot (see Cleaning

 

 

clogged

 

and Maintenance, page 25)

Gas odor even when control

1.

Gas leak. See Warning

1.

Locate and correct all leaks

knob is in OFF position

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

tions, page 16)

 

2.

Control valve or gas control

2.

Replace control valve or gas

 

 

defective

 

control

Gas odor during combustion

1.

Foreign matter between con-

1.

Take apart gas tubing and

 

 

trol valve and burner

 

remove foreign matter

 

2.

Gas leak. See Warning

2.

Locate and correct all leaks

 

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

tions, page 16)

Dark residue on logs inside

1.

Improper log placement

1.

Properly locate logs (see In-

of their fireplace. Note: After

2.

Drafts or other air currents

 

stalling Logs, page 17)

removing all causes of residue

2.

Eliminate source of drafts

deposits, completely clean fire-

 

affecting flame pattern

 

around heater

place and appliance off residue

3.

Air holes at burner inlet

3.

Clean out air holes at burner

before reusing appliance

 

blocked

 

inlet. Periodically repeat as

 

 

 

 

needed

 

4.

Burner flame holes blocked

4.

Remove blockage

Log set cycles to pilot, but room

1.

Thermostat sensing bulb needs

1.

Reposition thermostat sensing

temperature drops to a lower

 

to be repositioned (Thermo-

 

bulb

than ideal level before log set

 

stat-Controlled Models Only)

 

 

comes back on

2.

Hand-held remote control is

2.

Move hand-held remote control

 

 

too close to heater (Remote-

 

 

 

unit farther away from the heater

 

 

Ready Models Only)

 

 

 

 

 

30

www.desatech.com

113192-01D

Page 30
Image 30
Desa VSGF36NR, VSGF36PR WARNING If you smell gas Shut off gas supply, Do not try to light any appliance, Continued, Remedy