Desa VTD-18P-BTB, VTD-24P-PDG Troubleshooting, Observed Problem, Possible Cause, Remedy

Models: VTD-24P-BTB VTD-18P-BTB VTD-24P-PDG VTD-18N-BTB VTD-18N-PDG

1 26
Download 26 pages 39.78 Kb
Page 14
Image 14
TROUBLESHOOTING

14

TROUBLESHOOTING

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM WARNING: Turn off and un- plug appliance and let cool before servicing.Only a qualified service person should service and repair heater.

POSSIBLE CAUSE CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot.This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

When ignitor button is pressed, there is no

1.

Ignitor electrode not connected to ignitor

1.

Reconnect ignitor cable

spark at ODS/pilot

 

cable

 

 

 

 

2.

Ignitor cable pinched or wet

2.

Free ignitor cable if pinched by any

 

 

 

 

metal or tubing. Keep ignitor cable dry

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding piezo ignitor to base

 

 

 

 

panel of log set. Nut is located behind

 

 

 

 

base panel.

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

6.

Ignitor electrode positioned wrong or

6.

Replace pilot assembly for remote-ready

 

 

broken

 

units; Replace ignitor electrode for vari-

 

 

 

 

able manually controlled units

 

 

 

 

 

 

When ignitor button is pressed, there is spark

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

at ODS/pilot but no ignition

 

shutoff valve closed

 

shutoff valve

 

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

 

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

PILOT position

 

position

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

Repeat igniting operation until air is

 

 

 

 

removed

 

5.

Depleted gas supply (propane/LP

5.

Contact local propane/LP gas company

 

 

only)

6.

Clean ODS/pilot (see Cleaning and

 

6.

ODS/pilot is clogged

 

Maintenance, page 13) or replace

 

 

 

 

ODS/pilot assembly

 

7.

Gas regulator setting is not correct

7.

Replace gas regulator

ODS/pilot lights but flame goes out when control knob is released

1.Control knob not fully pressed in

2.Control knob not pressed in long enough

3.Safety interlock system has been triggered

4.Equipment shutoff valve not fully open

5.Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This prob- lem could be caused by one or both of the following:

A)Low gas pressure

B)Dirty or partially clogged ODS/ pilot

6.Thermocouple connection loose at con- trol valve

1.Press in control knob fully

2.After ODS/pilot lights, keep control knob pressed in 30 seconds

3.Wait one minute for safety interlock sys- tem to reset. Repeat ignition operation

4.Fully open equipment shutoff valve

5.A) Contact local natural or propane/LP gas company

B) Clean ODS/pilot (see Cleaning and Maintenance, page 13) or replace ODS/ pilot assembly

6.Hand tighten until snug, then tighten 1/4 turn more

7.Replace pilot assembly

8.Replace control valve

REMEDYManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundFor more information, visit www.desatech.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background