PRODUCT FEATURES PRE-INSTALLATION PREPARATION

Location and Space Requirements

PRODUCT FEATURES

These are a few facts that can help you understand and enjoy your direct-vent fireplace:

The venting system may be routed to the outside of your home in several ways. It may vent through the roof (vertical) or it may vent to an outside/exterior wall (horizontal). The vent pipe in- stallation is very important to allow for proper operation. You must follow the venting instructions very carefully for either vertical or horizontal applications.

This fireplace may be installed in any room of your house provided all local codes and these installation instructions are followed.

This fireplace does not require electricity to operate.

Only the blower requires electricity if installed and if you plan to install the blower at a later date, do not forget to wire the outlet at the bottom of the fireplace when framing.

A piezo ignitor and ceramic electrode create spark to ignite the pilot light. It does not require any matches, batteries or any other sources of ignition to light the pilot.

Each time you turn on your fireplace, you may notice some amount of condensation on the inside of the fireplace glass. This is normal and will disappear after 10-20 minutes of operation.

Your direct-vent gas fireplace system (fireplace and venting) is a balanced and sealed gas operating unit. It requires approximately 10-20 minutes of operating time before the flame pattern stabilizes.

PRE-INSTALLATION

PREPARATION

LOCATION AND SPACE REQUIREMENTS

Determine the safest and most efficient location for your DESA direct-vent fireplace. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows or doors. Figure 2 shows some common locations. Be aware of all restrictions and precautions before deciding the exact location for your fireplace and termination cap.

When deciding the location of your fireplace, follow these rules:

Do not connect this fireplace venting to a chimney flue serving a separate solid-fuel burning fireplace or appliance.

Due to high temperatures, do not locate this fireplace in high traf- fic areas, windy or drafty areas, or near furniture or draperies.

Proper clearances must be maintained.

If your fireplace is to be installed directly on carpeting, vinyl tile, or any combustible material other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace. See Figure 3.

Your fireplace is designed to be used in zero clearance installa- tions. Wall or framing material can be placed directly against any exterior surface on the back, sides, or top of your fireplace, except where standoff spacers are integrally attached. If stand- off spacers are attached to your fireplace, these spacers can be placed directly against wall or framing material. See framing details on page 5.

If you plan on installing a television or entertainment center re- cessed above your fireplace, it is recommended that you main- tain a minimum 18" above top of louver opening.

When locating termination cap, it is important to observe the minimum clearances shown in Figure 7, page 6.

If recessing into a wall, you can avoid extra framing by position- ing your fireplace against an already existing framing member.

Do not recess termination cap into a wall or siding.

You may paint the termination cap with 450ºF (232ºC) heat- resistant paint to coordinate with the exterior finish.

There must not be any obstruction such as bushes, garden sheds, fences, decks, or utility buildings within 24" from the front of the termination cap.

Do not locate termination cap where excessive snow or ice build up may occur. Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting system. When using snow blowers, do not direct snow towards vent termina- tion area.

Flush with a wall

Through exterior wall enclosed in a chase

Corner installation

Figure 2 - Common Fireplace Locations

36 1/4"

23 1/4"

48"

Figure 3 - Fireplace Bottom Dimensions

For..com

111907-01B

Page 4
Image 4
Desa V)V42EPA(1) SERIES, V)V42ENA(1) SERIES installation manual Product Features, PRE-INSTALLATION Preparation

V)V42EPA(1) SERIES, V)V42ENA(1) SERIES specifications

The Desa V)V42EPA(1) and V)V42ENA(1) series represent a significant advancement in energy-efficient technologies, emphasizing performance, environmental sustainability, and user comfort. These innovative products have been meticulously designed for various applications, catering to residential, commercial, and industrial energy needs.

One of the standout features of the V)V42EPA(1) and V)V42ENA(1) series is their exceptional energy efficiency. Equipped with advanced integrated circuit technology, these devices optimize power consumption, reducing utility bills while minimizing carbon footprint. The utilization of cutting-edge materials in their construction ensures durability and long-lasting performance, making them an excellent investment for users seeking reliability.

The V)V42EPA(1) series integrates innovative heat exchange technology, allowing for superior thermal performance. This feature ensures quick heat delivery, enhancing overall efficiency while maintaining a comfortable indoor environment. Additionally, the models within this series are designed to operate quietly, making them suitable for settings where noise reduction is paramount, such as homes and offices.

Meanwhile, the V)V42ENA(1) series boasts advanced air filtration capabilities. These units incorporate sophisticated purification systems that significantly reduce allergens, dust, and other pollutants from the air. This feature not only contributes to improved indoor air quality but also facilitates a healthier living or working environment.

Another critical characteristic of both series is their user-friendly interface. They are equipped with intuitive control panels that simplify adjustments and enhance user experience. Remote control capabilities further allow users to manage settings from a distance, adding convenience to day-to-day operation.

The smart technology integration in the V)V42EPA(1) and V)V42ENA(1) series enables connectivity with smart home systems. This functionality allows users to monitor and control their energy consumption seamlessly, further promoting an eco-friendly lifestyle.

Both series are also designed with sustainability in mind. They utilize refrigerants with lower global warming potential, aligning with international environmental standards. This commitment to sustainability not only benefits the planet but also ensures compliance with regulatory requirements.

In conclusion, the Desa V)V42EPA(1) and V)V42ENA(1) series offer a blend of efficiency, comfort, and eco-friendliness. With their advanced technologies, user-centric design, and commitment to sustainability, these series set a benchmark in the energy solutions market, making them ideal choices for anyone looking to improve their energy management and overall indoor environment.