4

PRODUCT FEATURES PRE-INSTALLATION PREPARATION

Location and Space Requirements

PRODUCT FEATURES

These are a few facts that can help you understand and enjoy your direct-vent fireplace:

The venting system may be routed to the outside of your home in several ways. It may vent through the roof (vertical) or it may vent to an outside/exterior wall (horizontal). The vent pipe instal- lation is very important to allow for proper operation. You must follow the venting instructions very carefully for either vertical or horizontal applications.

This fireplace may be installed in any room of your house provided all local codes and these installation instructions are followed.

The blower requires electricity if installed. If you plan to install the blower at a later date, do not forget to wire the outlet at the bottom of the fireplace when framing.

Each time you turn on your fireplace, you may notice some amount of condensation on the inside of the fireplace glass. This is normal and will disappear after 10-20 minutes of operation.

Your direct-vent gas fireplace system (fireplace and venting) is a balanced and sealed gas operating unit. It requires approximately 10- 20 minutes of operating time before the flame pattern stabilizes.

If you plan on installing a television or entertainment center re- cessed above your fireplace, it is recommended that you maintain a minimum 18" above top of louver opening.

When locating termination cap, it is important to observe the minimum clearances shown in Figure 7, page 6.

If recessing into a wall, you can avoid extra framing by position- ing your fireplace against an already existing framing member.

Do not recess termination cap into a wall or siding.

You may paint the termination cap with 450ºF (232ºC) heat- resistant paint to coordinate with the exterior finish.

There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24" from the front of the termination cap.

Do not locate termination cap where excessive snow or ice build up may occur. Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting system. When using snow blowers, do not direct snow towards vent termination area.

PRE-INSTALLATION

PREPARATION

LOCATION AND SPACE REQUIREMENTS

Determine the safest and most efficient location for your DESA direct-vent fireplace. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows or doors. Figure 2 shows some common locations. Be aware of all restrictions and precautions before deciding the exact location for your fireplace and termination cap.

When deciding the location of your fireplace, follow these rules:

Do not connect this fireplace venting to a chimney flue serving a separate solid-fuel burning fireplace or appliance.

Due to high temperatures, do not locate this fireplace in high traf- fic areas, windy or drafty areas or near furniture or draperies.

Proper clearances must be maintained.

If your fireplace is to be installed directly on carpeting, vinyl tile or any combustible material other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace. See Figure 3.

Your fireplace is designed to be used in zero clearance instal- lations. Wall or framing material can be placed directly against any exterior surface on the back, sides or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing material. See framing details on page 5.

Flush with a wall

Through exterior wall enclosed in a chase

Figure 2 - Common Fireplace Locations

29"

21 1/8"

41"

Figure 3 - Fireplace Bottom Dimensions

Corner installation

www.desatech.com

116235-01A

Page 4
Image 4
Desa (V)VC36NE Series installation manual Product Features, PRE-INSTALLATION Preparation, Location and Space Requirements

(V)VC36NE Series specifications

The Desa (V)VC36NE Series is a revolutionary heating solution designed for both residential and commercial application. This series combines advanced technologies with user-friendly features, making it a versatile option for consumers looking for reliable and efficient heating solutions.

One of the standout features of the VC36NE Series is its high-efficiency heating capabilities. Utilizing cutting-edge technology, this series achieves energy efficiency ratings that surpass traditional heating systems. This means that users can enjoy a comfortable indoor environment while significantly reducing their energy consumption and costs.

Another key characteristic of the VC36NE Series is its compact design. The sleek and modern aesthetics allow it to blend seamlessly into various interior designs while occupying minimal space. This makes it ideal for smaller homes or apartments where every square inch counts. The unit's lightweight construction also allows for easy installation, which can be completed by professionals or even handy homeowners.

The Desa VC36NE Series is equipped with advanced control features that provide users with full command over their heating system. A digital thermostat ensures accurate temperature regulation, allowing users to set their desired comfort level with precision. Additionally, the unit includes programmable settings, giving users the ability to create customized heating schedules tailored to their lifestyle.

Safety is paramount in the design of the VC36NE Series. It incorporates multiple safety features, including overheat protection and flame failure devices, ensuring peace of mind while the unit is in operation. This makes it a suitable option for families with children or pets.

In terms of modernization, the VC36NE Series often integrates smart technology, allowing users to connect the heating system to their smartphones or smart home networks. This feature enables remote control of heating schedules from anywhere, enhancing convenience and energy management.

Durability is another hallmark of the Desa VC36NE Series. Constructed with high-quality materials, the unit is designed to withstand the rigors of daily use over long periods. This robust construction ensures that users receive a reliable heating solution that will serve them for years to come.

In conclusion, the Desa (V)VC36NE Series stands out for its efficiency, compact design, advanced controls, safety features, connectivity, and durability. It is an exemplary choice for anyone seeking a modern heating solution that meets both performance and aesthetic requirements.