VENTING INSTALLATION INSTRUCTIONS Installation Planning

VENTING INSTALLATION INSTRUCTIONS

Continued

INSTALLATION PLANNING

There are two basic types of direct-vent installation:

Horizontal Termination

Vertical Termination

Horizontal Termination Installation

IMPORTANT: Horizontal square terminations require only in- ner portion of wall firestop. Horizontal installations using round termination require exterior portion of wall firestop (see Figure 14, page 10).

1.Set the fireplace in its desired location and determine the route your horizontal venting will take. Do not secure the fireplace until all venting has been installed. Some installations require sliding the fireplace in and out of position to make final vent- ing connections. Figures 14 through 18 on pages 10 through 12 show different configurations for venting with horizontal termination that will help you decide which application best suits your installation. Check to see if wall studs or roof rafters are in the path of your desired venting route. If they are, you may want to adjust the location of the fireplace.

2.Direct vent pipe sections and components are designed with special twist-lock connections.

Twist-Lock Procedure: The female ends of the pipes have locking lugs (indentations). These lugs will slide straight into matching slots on the male ends of adjacent pipes. Push pipe sections together and twist one section clockwise approxi- mately one-quarter turn until the sections are fully locked (see Figure 8). Note: Horizontal runs of vent must be supported every three feet. Use wall straps for this purpose.

3.Use a 45° elbow to connect venting system to fireplace flue collar. The elbow is designed to be twist-locked onto the flue collar as described in step 2. IMPORTANT: Do not attempt to alter the configuration of the elbow by cutting, twisting, bending, etc.

4.Assemble the desired combination of pipe and elbows to the fireplace flue collar. If there are long portions of venting run, pre-assembled pipe sections may be installed as subassemblies for convenience.

5.Carefully determine the location where the vent pipe assembly will penetrate the outside wall. The center of the hole should line up with the center-line of the horizontal vent pipe. Mark the wall for a 10 3/4" x 10 3/4" square hole. Cut and frame the square hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of noncombustible material, such as masonry block or concrete, a 8 1/2" hole with zero clearance is acceptable (see Figure 9).

Male

Female Slots

Locking

Lugs

Figure 8 - Vent Pipe Connections

Vent Opening

 

Combustible Wall

10 3/4" Inside Framing

10 3/4"

(273 mm)

(273 mm)

 

10 3/4"

 

(273 mm)

 

(Framing

Vent Opening

Detail)

 

Noncombustible Wall

 

8 1/2"

 

(216 mm)

 

 

Center

 

of Hole

Figure 9 - Vent Opening Requirements

www.desatech.com

116235-01A

Page 8
Image 8
Desa (V)VC36NE Series Installation Planning, Horizontal Termination Installation, Male Female Slots Locking Lugs, Center

(V)VC36NE Series specifications

The Desa (V)VC36NE Series is a revolutionary heating solution designed for both residential and commercial application. This series combines advanced technologies with user-friendly features, making it a versatile option for consumers looking for reliable and efficient heating solutions.

One of the standout features of the VC36NE Series is its high-efficiency heating capabilities. Utilizing cutting-edge technology, this series achieves energy efficiency ratings that surpass traditional heating systems. This means that users can enjoy a comfortable indoor environment while significantly reducing their energy consumption and costs.

Another key characteristic of the VC36NE Series is its compact design. The sleek and modern aesthetics allow it to blend seamlessly into various interior designs while occupying minimal space. This makes it ideal for smaller homes or apartments where every square inch counts. The unit's lightweight construction also allows for easy installation, which can be completed by professionals or even handy homeowners.

The Desa VC36NE Series is equipped with advanced control features that provide users with full command over their heating system. A digital thermostat ensures accurate temperature regulation, allowing users to set their desired comfort level with precision. Additionally, the unit includes programmable settings, giving users the ability to create customized heating schedules tailored to their lifestyle.

Safety is paramount in the design of the VC36NE Series. It incorporates multiple safety features, including overheat protection and flame failure devices, ensuring peace of mind while the unit is in operation. This makes it a suitable option for families with children or pets.

In terms of modernization, the VC36NE Series often integrates smart technology, allowing users to connect the heating system to their smartphones or smart home networks. This feature enables remote control of heating schedules from anywhere, enhancing convenience and energy management.

Durability is another hallmark of the Desa VC36NE Series. Constructed with high-quality materials, the unit is designed to withstand the rigors of daily use over long periods. This robust construction ensures that users receive a reliable heating solution that will serve them for years to come.

In conclusion, the Desa (V)VC36NE Series stands out for its efficiency, compact design, advanced controls, safety features, connectivity, and durability. It is an exemplary choice for anyone seeking a modern heating solution that meets both performance and aesthetic requirements.