VENTED NATURAL GAS LOGS

SAFETY

INFORMATION

WARNINGS

WARNING: Keep flue open when operating unit.

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this log set. Im- proper use of this log set can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the log set may not be working properly. Get fresh air at once! Have log set serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural Gas: Natural gas is odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this log set.

WARNING: Any change to this log set or its controls can be dangerous.

1.This appliance, as supplied, is only for use with the type of gas indicated on the rating plate. This appliance is con- vertible for use with propane/LP, using the GA9000 or GA9100 pilot kit.

2.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

3.Never install the log set

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the log set

in high traffic areas

in windy or drafty areas

4.Before installing in a solid fuel burn- ing fireplace, the chimney flue and fire- box must be cleaned of soot, creosote, ashes, and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage.

5.You must operate this log set with a fire- place screen in place. Make sure fireplace screen is closed before running log set.

6.This log set is designed to be smoke- less. If logs ever appear to smoke, turn off appliance and call a qualified ser- vice person. Note: During initial op- eration, slight smoking could occur due to log curing and the burning of manu- facturing residues. You may wish to add more ventilation by opening a window.

7.To reduce the creation of soot, follow the instructions in Cleaning and Main- tenance, page 13.

8.Do not allow fans to blow directly into the fireplace. Avoid any drafts that al- ter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can increase sooting.

9.Do not use a blower insert, heat ex- changer insert or other accessory not approved for use with this log set.

10.This log set needs fresh, outside air ven- tilation to run properly. See Air for Combustion and Ventilation, pages 4 through 6.

11.Do not run log set

where flammable liquids or vapors are used or stored

under dusty conditions

12.Do not burn solid fuel in the fireplace after installing the log set. Do not use this log set to cook food or burn paper or other objects.

13.Log set becomes very hot when in use. Keep children and adults away from hot surface to avoid burns or clothing igni- tion. Log set will remain hot for a time after shutdown. Allow surface to cool before touching.

14.Carefully supervise young children when they are in the room with log set.

15.Do not use appliance if any part has been exposed to or under water. Immediately call a qualified service technician to in- spect the room appliance and to replace any part of the control system (if using GA9000 or GA9100) and any gas con- trol which has been under water.

16.To help prevent breakage, new logs must be broken-in (see Curing Logs page 12).

17.Turn log set off and let cool before ser- vicing, installing, or repairing. Only a qualified service person should install, service, or repair log set.

2

901267

Page 2
Image 2
Desa VVMR24, VVMR18 installation manual Vented Natural GAS Logs, Safety Information

VVMR18, VVMR24 specifications

Desa VVMR18 and VVMR24 are advanced solutions designed to enhance the efficiency of commercial and industrial heating systems. These models represent a significant leap in technology within the realm of industrial heaters, emphasizing energy efficiency, reliability, and user-friendly operation.

One of the main features of both the VVMR18 and VVMR24 models is their highly efficient heat exchange technology. The design incorporates a compact heat exchanger that maximizes thermal efficiency while minimizing energy waste. This means that users can not only save on operational costs but also reduce their carbon footprint, aligning with global sustainability goals.

The VVMR series utilizes advanced control systems that allow for precise temperature regulation and monitoring. These control systems are equipped with intelligent algorithms that adapt to varying load demands and external conditions, ensuring optimal performance at all times. This feature is particularly beneficial in environments where temperature fluctuations are common, providing stable heating without the need for constant manual adjustment.

In terms of construction, both models boast robust builds, designed to withstand the rigors of industrial use. The use of high-quality materials enhances durability and longevity, reducing maintenance requirements and extending the lifespan of the units. Additionally, their modular design facilitates easy installation and servicing, which is critical in industrial settings where downtime can be costly.

Safety is another critical characteristic of the VVMR18 and VVMR24 models. They come equipped with multiple safety features, including over-temperature protection and pressure relief systems, ensuring reliable operation without compromising on safety. These features are essential in industrial environments where safety regulations are paramount.

In conclusion, the Desa VVMR18 and VVMR24 offer a blend of efficiency, advanced technology, and robust design. Their intelligent control systems, efficient heat exchange technology, and focus on safety make them ideal choices for businesses seeking reliable heating solutions. Investing in these models not only supports operational efficiency but also promotes a commitment to environmental responsibility, making them a wise choice for modern industrial applications.