16
OPERATING HEATER
Optional Remote Operation (Cont.)
INSPECTING BURNERS
Pilot Flame Pattern
Burner Flame Pattern
OPERATING HEATER
Continued
GHRCTA Series Operation
2b. Press the AUTO/ON/OFF button on the
•In the ON mode, the burners will ignite. The heater is in manual mode when ON is lit.
•In the AUTO mode, the thermostat in the
IMPORTANT: This remote control has been specially en- gineered to take an air temperature sample every 5.5 minutes in the AUTO mode. It will not respond immedi- ately to the temperature setting being turned up or down. IMPORTANT: The
3.To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit.
IMPORTANT: To turn the pilot off, manually turn the con- trol knob on the heater to the OFF position.
Flame Adjustment Knob | Control Knob in |
On Position |
INSPECTING BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 27 shows a correct pilot flame pattern. Figure 28 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. When the thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 28
•turn heater off (see To Turn Off Gas to Appliance, page 15)
•see Troubleshooting, pages 18 through 20
Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.
Pilot Burner
Thermocouple
Figure 27 - Correct Pilot Flame Pattern (Propane/LP Pilot Shown)
Pilot Burner
Thermocouple
IH |
| F | PIL |
ON |
| O | |
O | F | T | |
|
| ||
OFF |
| O | |
|
| ||
|
| N | |
REMOTE |
|
| |
|
|
| |
LO |
|
|
|
Selector Switch in Remote Position
(Optional Remote Control)
Figure 25 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation
Figure 28 - Incorrect Pilot Flame Pattern (Propane/LP Pilot Shown)
BURNER FLAME PATTERN
Figure 29 shows a correct burner flame pattern. Figure 30 shows an incorrect burner flame pattern. If burner flame pattern is incorrect,
•turn heater off (see To Turn Off Gas to Appliance, page 15)
•see Troubleshooting, pages 18 through 20
Shows
Temperature
Setting
The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has
been Selected
Increases Room
Temperature in
AUTO Mode
Decreases Room
Temperature in
AUTO Mode
Turns Burners On or Off and Allows You to Choose the Auto Setting
Figure 29 - Correct Flame Pattern
Figure 26 - Thermostat
Figure 30 - Incorrect Flame Pattern