OWNER’S MANUAL
INSTALLATION
Continued
MANTEL CLEARANCES
In addition to meeting noncombustible ma- terial clearances, you must also meet re- quired clearances between fireplace open- ings and mantel shelf on each side of the fireplace. If you do not meet the clearances listed below, you will need a hood.
DETERMINING MINIMUM MANTEL CLEARANCE
If you meet minimum clearance between mantel shelf and top of fireplace opening, a
10"
8"
6"
2 1/2"
Minimum Non- |
|
| (A) | |
| ||||
Combustible | ||||
| ||||
Material |
| |||
|
|
| 12" | |
|
|
|
|
Mantel Shelf
18" |
| 20" | 22" |
| |||
|
|
|
|
Underside of
Mantel Shelf
All minimum distances are in inches
24"
Top of Fireplace
Opening
hood is not required (see Figure 6).
DETERMINING MINIMUM MANTEL CLEARANCE WHEN USING A HOOD
If minimum clearances in Figure 6 are not met, you must have a hood. When using a
Minimum Non- | Distances to |
Combustible | Underside of |
Material Height | Mantel |
Figure 6 - Minimum Mantel Clearances Without Using Hood
hood there are still certain minimum mantel clearances required. Follow minimum clear- ances shown in Figure 7 when using hood.
NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following:
•operate the logs only with the flue damper open
•raise the mantel to an accept- able height
•remove the mantel
12"
10"
8"
6"
2 1/2"
Minimum Non-
Combustible
Material
Mantel Shelf
Underside of
Mantel Shelf
All minimum distances are in inches
8" | 12" | 15" | 18" | 20" |
Min. |
|
|
|
|
Top of Fireplace
Opening
FLOOR CLEARANCES
A.If installing appliance on the floor level, you must maintain the minimum dis- tance of 14" to combustibles (see Fig- ure 8).
B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combus- tible flooring (see Figure 9).
Hood (GA6050, | Distances to |
GA6052 or GA6053) | Underside of |
| Mantel |
Figure 7 - Minimum Mantel Clearances When Using Hood
| Combustible |
|
|
14" | Material | Hearth | Combustible |
| |||
Min. |
| 5” | Material |
|
|
| |
Min. |
| ||
|
| ||
Figure 8 - Minimum Fireplace Clearances | Figure 9 - Minimum Fireplace Clearances | ||
If Installed at Floor Level |
| Above Combustible Flooring | |
|
|
| Continued |
104675 | 9 |