Desa VYM27PR Mantel Clearances, Determining Minimum Mantel Clearance, Floor Clearances

Models: VYM27PR

1 26
Download 26 pages 17.82 Kb
Page 9
Image 9

OWNER’S MANUAL

INSTALLATION

Continued

MANTEL CLEARANCES

In addition to meeting noncombustible ma- terial clearances, you must also meet re- quired clearances between fireplace open- ings and mantel shelf on each side of the fireplace. If you do not meet the clearances listed below, you will need a hood.

DETERMINING MINIMUM MANTEL CLEARANCE

If you meet minimum clearance between mantel shelf and top of fireplace opening, a

10"

8"

6"

2 1/2"

Minimum Non-

 

 

(A)

 

Combustible

 

Material

 

 

 

 

12"

 

 

 

 

Mantel Shelf

18"

 

20"

22"

 

 

 

 

 

Underside of

Mantel Shelf

All minimum distances are in inches

24"

Top of Fireplace

Opening

hood is not required (see Figure 6).

DETERMINING MINIMUM MANTEL CLEARANCE WHEN USING A HOOD

If minimum clearances in Figure 6 are not met, you must have a hood. When using a

Minimum Non-

Distances to

Combustible

Underside of

Material Height

Mantel

Figure 6 - Minimum Mantel Clearances Without Using Hood

hood there are still certain minimum mantel clearances required. Follow minimum clear- ances shown in Figure 7 when using hood.

NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following:

operate the logs only with the flue damper open

raise the mantel to an accept- able height

remove the mantel

12"

10"

8"

6"

2 1/2"

Minimum Non-

Combustible

Material

Mantel Shelf

Underside of

Mantel Shelf

All minimum distances are in inches

8"

12"

15"

18"

20"

Min.

 

 

 

 

Top of Fireplace

Opening

FLOOR CLEARANCES

A.If installing appliance on the floor level, you must maintain the minimum dis- tance of 14" to combustibles (see Fig- ure 8).

B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combus- tible flooring (see Figure 9).

Hood (GA6050,

Distances to

GA6052 or GA6053)

Underside of

 

Mantel

Figure 7 - Minimum Mantel Clearances When Using Hood

 

Combustible

 

 

14"

Material

Hearth

Combustible

 

Min.

 

5”

Material

 

 

 

Non-Combustible Material

Min.

 

 

 

Figure 8 - Minimum Fireplace Clearances

Figure 9 - Minimum Fireplace Clearances

If Installed at Floor Level

 

Above Combustible Flooring

 

 

 

Continued

104675

9

Page 9
Image 9
Desa VYM27PR installation manual Mantel Clearances, Determining Minimum Mantel Clearance, Floor Clearances